COMPARATIVE STUDY
JOURNAL ARTICLE

Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage

Akiyasu Kanamori, Azusa Nagai-Kusuhara, Michael F T Escaño, Hidetaka Maeda, Makoto Nakamura, Akira Negi
Graefe's Archive for Clinical and Experimental Ophthalmology 2006, 244 (1): 58-68
16044326

BACKGROUND: The aim was to compare the ability of confocal scanning laser ophthalmoscopy (CSLO), scanning laser polarimetry (SLP), and optical coherence tomography (OCT) to discriminate eyes with ocular hypertension (OHT), glaucoma-suspect eyes (GS) or early glaucomatous eyes (EG) from normal eyes.

METHODS: Ocular hypertension, GS, and EG were defined as normal disc with intraocular pressure >21 mmHg, glaucomatous disc without visual field loss, and glaucomatous disc accompanying the early glaucomatous visual filed loss respectively. Ninety-three normal eyes, 26 OHT, 55 GS, and 67 EG were enrolled. Optic disc configuration was analyzed by CSLO (version 3.04), whereas retinal nerve fiber layer thickness was analyzed by SLP (GDx-VCC; version 5.3.2) and OCT-1 (version A6X1) in each individual. The measurements were compared in the four groups of patients. Receiver operating characteristic curve (ROC) and area under the curve (AUC) discriminating OHT, GS or EG from normal eyes were compared for the three instruments.

RESULTS: Most parameters in GS and EG eyes showed significant differences compared with normal eyes. However, there were few significant differences between normal and OHT eyes. No significant differences were observed in AUCs between SLP and OCT. In EG eyes, the greatest AUC parameter in OCT (inferior--120; 0.932) had a higher AUC than that in CSLO (vertical cup/disc ratio; 0.845; P=0.017). In GS, the greatest AUC parameter in OCT (average retinal nerve fiber layer [RNFL] thickness; 0.869; P=0.002) and SLP (nerve fiber indicator [NFI]; 0.875; P=0.002) had higher AUC than that in CSLO (vertical cup/disc ratio; 0.720).

CONCLUSIONS: Three instruments were useful in identifying GS and EG eyes. For glaucomatous eyes with or without early visual field defects, SLP and OCT performed similarly or had better discriminating abilities compared with CSLO.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
16044326
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"