A three-dimensional registration method for automated fusion of micro PET-CT-SPECT whole-body images.
IEEE Transactions on Medical Imaging 2005 July
Micro positron emission tomography (PET) and micro single-photon emission computed tomography (SPECT), used for imaging small animals, have become essential tools in developing new pharmaceuticals and can be used, among other things, to test new therapeutic approaches in animal models of human disease, as well as to image gene expression. These imaging techniques can be used noninvasively in both detection and quantification. However, functional images provide little information on the structure of tissues and organs, which makes the localization of lesions difficult. Image fusion techniques can be exploited to map the functional images to structural images, such as X-ray computed tomography (CT), to support target identification and to facilitate the interpretation of PET or SPECT studies. Furthermore, the mapping of two functional images of SPECT and PET on a structural CT image can be beneficial for those in vivo studies that require two biological processes to be monitored simultaneously. This paper proposes an automated method for registering PET, CT, and SPECT images for small animals. A calibration phantom and a holder were used to determine the relationship among three-dimensional fields of view of various modalities. The holder was arranged in fixed positions on the couches of the scanners, and the spatial transformation matrix between the modalities was held unchanged. As long as objects were scanned together with the holder, the predetermined matrix could register the acquired tomograms from different modalities, independently of the imaged objects. In this work, the PET scan was performed by Concorde's microPET R4 scanner, and the SPECT and CT data were obtained using the Gamma Medica's X-SPECT/CT system. Fusion studies on phantoms and animals have been successfully performed using this method. For microPET-CT fusion, the maximum registration errors were 0.21 mm +/- 0.14 mm, 0.26 mm +/- 0.14 mm, and 0.45 mm +/- 0.34 mm in the X (right-left), Y (upper lower), and Z (rostral-caudal) directions, respectively; for the microPET-SPECT fusion, they were 0.24 mm +/- 0.14 mm, 0.28 mm +/- 0.15 mm, and 0.54 mm +/- 0.35 mm in the X, Y, and Z directions, respectively. The results indicate that this simple method can be used in routine fusion studies.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app