[Modified ECG-guidance for optimal central venous catheter tip positioning. A transesophageal echocardiography controlled study].
Der Anaesthesist 2005 October
BACKGROUND: Intraatrial electrocardiography (ECG) is a well-established method for central-venous catheter (CVC) placement and an intraatrial position is assumed, when a significantly increased P-wave is registered. However, an increase in P-wave amplitude also occurs in other positions. Therefore we evaluated CVC tip positioning by means of transesophageal echocardiography (TEE) at a maximum P-wave amplitude.
PATIENTS AND METHODS: In this prospective randomized study the right or left internal jugular vein was cannulated with 100 patients in each group and catheter tip positioning was guided by means of ECG. The catheter was fixed at the position of maximum P-wave amplitude and the insertion depth was registered. The relationship of the CVC tip position to the superior edge of the crista terminalis was demonstrated with the help of TEE.
RESULTS: In all patients the catheter tip was found +/- 0.5 cm from the superior edge of the crista terminalis at the transition from the superior vena cava to the right atrium. On x-ray control, all catheters ran along the length of the vessel wall of the superior vena cava.
CONCLUSIONS: A maximum P-wave is derived even at the entrance to the right atrium. This explains why ECG-guided CVC placement -- based on the largest P-wave amplitude -- consistently resulted in correct positioning of the CVC tip at the transition from the superior vena cava to the right atrium.
PATIENTS AND METHODS: In this prospective randomized study the right or left internal jugular vein was cannulated with 100 patients in each group and catheter tip positioning was guided by means of ECG. The catheter was fixed at the position of maximum P-wave amplitude and the insertion depth was registered. The relationship of the CVC tip position to the superior edge of the crista terminalis was demonstrated with the help of TEE.
RESULTS: In all patients the catheter tip was found +/- 0.5 cm from the superior edge of the crista terminalis at the transition from the superior vena cava to the right atrium. On x-ray control, all catheters ran along the length of the vessel wall of the superior vena cava.
CONCLUSIONS: A maximum P-wave is derived even at the entrance to the right atrium. This explains why ECG-guided CVC placement -- based on the largest P-wave amplitude -- consistently resulted in correct positioning of the CVC tip at the transition from the superior vena cava to the right atrium.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app