JOURNAL ARTICLE

Temporary hemodialysis catheters as a long-term vascular access in chronic hemodialysis patients

Rafael Ponikvar, Jadranka Buturović-Ponikvar
Therapeutic Apheresis and Dialysis 2005, 9 (3): 250-3
15967000
The objective was to review our experience with temporary, precurved, jugular catheters used for long-term vascular access in chronic hemodialysis patients. Thirty chronic hemodialysis patients, 14 men and 16 women, with an average age of 65.3 +/- 13.5 years (30-90 years), treated by dialysis for 1 month to 30 years (average +/- SD, 6.3 +/- 8.1 years), had single lumen, 'temporary' precurved non-tunneled jugular catheters placed into the right jugular vein as permanent vascular access, with 4% trisodium citrate as a locking solution and mupirocin at the exit site. Hemodialysis catheters were used for vascular access on average for 9.1 +/- 6.5 months, (1-22.7 months), and for a total of 271.7 months (8151 days). Average catheter functioning time was 3.1 +/- 1.9 months (0.5-10 months). The total number of side-effects was 55 (6.7/1000 catheter days), including 26 cases of thrombosis (3.2/1000 catheter days), 9 ruptures of the catheter (1.1/1000 catheter days), 15 catheter malfunctions (1.8/1000 catheter days), 2 exit site infections (0.2/1000 catheter days), 2 bacteremias (0.2/1000 catheter days), 1 avulsion of the catheter (0.1/1000 catheter days), and 2 catheters were removed because an AV fistula was successfully used. In 21 patients single-needle hemodialysis was performed, mean blood flow 251 +/- 16 mL/min (250-300), mean Kt/V 0.96 +/- 0.16 (0.72-1.27) and in 9 patients double-needle hemodialysis was performed (catheter and peripheral vein) with mean blood flow 252 +/- 14 mL/min (200-300), mean Kt/V 1.63 +/- 0.25 (1.21-1.96). 'Temporary' jugular single lumen non-tunneled hemodialysis catheters, with 4% citrate as locking solution and mupirocin ointment at the exit site provided good long-term vascular access with acceptable functioning time and low infection rate. The main reasons for catheter exchange or removal were malfunction and mechanical damage of the catheter.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
15967000
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"