Simultaneous integrated intensity-modulated radiotherapy boost for locally advanced gynecological cancer: radiobiological and dosimetric considerations.

PURPOSE: Whole-pelvis irradiation (WPI) followed by a boost to the tumor site is the standard of practice for the radiotherapeutic management of locally advanced gynecologic cancers. The boost is frequently administered by use of brachytherapy or, occasionally, external-beam radiotherapy (EBRT) when brachytherapy does not provide sufficient coverage because of the size of the tumor or the geometry of the patient. In this work, we propose using an intensity-modulated radiotherapy (IMRT) simultaneous integrated boost (SIB), which is a single-phase process, to replace the conventional two-phase process involving WPI plus a boost. Radiobiological modeling is used to design appropriate regimens for the IMRT SIB. To demonstrate feasibility, a dosimetric study is carried out on an example patient.

METHODS AND MATERIALS: The standard linear-quadratic (LQ) model is used to calculate the biologically effective dose (BED) and equivalent uniform dose (EUD). A series of regimens that are biologically equivalent to those conventional two-phase treatments is calculated for the proposed SIB. A commercial inverse planning system (Corvus) was used to generate IMRT SIB plans for a sample patient case that used the newly designed fractionations. The dose-volume histogram (DVH) and EUD of both the target and normal structures for conventional treatments and the SIB are compared. A sparing factor was introduced to characterize the sparing of normal structures.

RESULTS: Fractionation regimes that are equivalent to the conventional treatments and are suitable for the IMRT SIB are deduced. For example, a SIB plan with 25 x 3.1 Gy (77.5 Gy) to a tumor is equivalent to a conventional treatment of EBRT of 45 Gy to the whole pelvis in 25 fractions plus a high-dose rate (HDR) brachytherapy boost with 30 Gy in 5 fractions. The normal tissue BED is found to be lower for the SIB plan than for the whole-pelvis plus HDR scheme when a sparing factor for the critical structures is considered. This finding suggests that the IMRT SIB has a better therapeutic ratio. Three IMRT SIB plans with 25 x 1.8 Gy to the pelvic nodes and 25 x 2.4 Gy (60 Gy), 25 x 2.8 Gy (70 Gy), and 25 x 3.2 Gy (80 Gy) to the tumor site were generated for the example patient case. The target coverage ranged from 94% to 95.5%. The sparing of bladder and rectum is significantly improved with the 60 to 70 Gy SIB treatments, as compared with the conventional treatments. The proposed SIB treatment can reduce the treatment time to 5 weeks.

CONCLUSIONS: An IMRT simultaneous integrated boost to replace the conventional two-phase treatments (whole pelvic irradiation followed by brachytherapy or EBRT boost) is radiobiologically and dosimetricaly feasible for locally advanced gynecological cancers that may not be amenable to brachytherapy for anatomic or medical reasons. In addition to its shorter treatment time, the proposed IMRT SIB can provide significant sparing to normal structures, which offers potential for dose escalation. Issues such as organ motion and changing anatomy as tumor responds still must be addressed.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app