JOURNAL ARTICLE
MULTICENTER STUDY

Multidetector-row computed tomography in suspected pulmonary embolism

Arnaud Perrier, Pierre-Marie Roy, Olivier Sanchez, Grégoire Le Gal, Guy Meyer, Anne-Laurence Gourdier, Alain Furber, Marie-Pierre Revel, Nigel Howarth, Alain Davido, Henri Bounameaux
New England Journal of Medicine 2005 April 28, 352 (17): 1760-8
15858185

BACKGROUND: Single-detector-row computed tomography (CT) has a low sensitivity for pulmonary embolism and must be combined with venous-compression ultrasonography of the lower limbs. We evaluated whether the use of D-dimer measurement and multidetector-row CT, without lower-limb ultrasonography, might safely rule out pulmonary embolism.

METHODS: We included 756 consecutive patients with clinically suspected pulmonary embolism from the emergency departments of three teaching hospitals and managed their cases according to a standardized sequential diagnostic strategy. All patients were followed for three months.

RESULTS: Pulmonary embolism was detected in 194 of the 756 patients (26 percent). Among the 82 patients with a high clinical probability of pulmonary embolism, multidetector-row CT showed pulmonary embolism in 78, and 1 patient had proximal deep venous thrombosis and a CT scan that was negative for pulmonary embolism. Of the 674 patients without a high probability of pulmonary embolism, 232 (34 percent) had a negative D-dimer assay and an uneventful follow-up; CT showed pulmonary embolism in 109 patients. CT and ultrasonography were negative in 318 patients, of whom 3 had a definite thromboembolic event and 2 died of possible pulmonary embolism during follow-up (three-month risk of thromboembolism, 1.7 percent; 95 percent confidence interval, 0.7 to 3.9). Two patients had proximal deep venous thrombosis and a negative CT scan (risk, 0.6 percent; 95 percent confidence interval, 0.2 to 2.2). The overall three-month risk of thromboembolism in patients without pulmonary embolism would have been 1.5 percent (95 percent confidence interval, 0.8 to 3.0) if the D-dimer assay and multidetector-row CT had been the only tests used to rule out pulmonary embolism and ultrasonography had not been performed.

CONCLUSIONS: Our data indicate the potential clinical use of a diagnostic strategy for ruling out pulmonary embolism on the basis of D-dimer testing and multidetector-row CT without lower-limb ultrasonography. A larger outcome study is needed before this approach can be adopted.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
15858185
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"