Percutaneous mitral valve repair for chronic ischemic mitral regurgitation: a real-time three-dimensional echocardiographic study in an ovine model.
Circulation 2005 May 4
BACKGROUND: Although surgical annuloplasty is the standard repair for ischemic mitral regurgitation (IMR), its application is limited by high morbidity and mortality. Using 2D and real-time 3D echocardiography in an ovine model of chronic IMR, we evaluated the geometric impact and short-term efficacy of a percutaneous transvenous catheter-based approach for mitral valve (MV) repair using a novel annuloplasty device placed in the coronary sinus.
METHODS AND RESULTS: Six sheep developed IMR 8 weeks after induced posterior myocardial infarction. An annuloplasty device optimized to reduce anterior-posterior (A-P) mitral annular dimension and MR was placed percutaneously in the coronary sinus. Mitral annular A-P and commissure-commissure dimensions and MV tenting area (MVTa) in 3 parallel A-P planes (medial, central, and lateral) were assessed by real-time 3D echocardiography with 3D software. The annuloplasty device reduced MR jet area from 5.4+/-2.6 to 1.3+/-0.9 cm2 (P<0.01), mitral annular A-P dimension in both systole and diastole (24.3+/-2.5 to 19.7+/-2.4 mm; P<0.03; 31.0+/-3.9 to 24.7+/-2.1 mm; P<0.001), and MVTa at mid systole in all 3 planes (153+/-46 to 93+/-24 mm2, P<0.01; 140+/-47 to 88+/-23 mm2, P<0.03; and 103+/-23 to 87+/-26 mm2, P<0.03).
CONCLUSIONS: Percutaneous coronary sinus-based mitral annuloplasty reduces chronic IMR by reducing mitral annular A-P diameter and MVTa. This suggests the potential clinical application of a new nonsurgical therapeutic approach in patients with IMR.
METHODS AND RESULTS: Six sheep developed IMR 8 weeks after induced posterior myocardial infarction. An annuloplasty device optimized to reduce anterior-posterior (A-P) mitral annular dimension and MR was placed percutaneously in the coronary sinus. Mitral annular A-P and commissure-commissure dimensions and MV tenting area (MVTa) in 3 parallel A-P planes (medial, central, and lateral) were assessed by real-time 3D echocardiography with 3D software. The annuloplasty device reduced MR jet area from 5.4+/-2.6 to 1.3+/-0.9 cm2 (P<0.01), mitral annular A-P dimension in both systole and diastole (24.3+/-2.5 to 19.7+/-2.4 mm; P<0.03; 31.0+/-3.9 to 24.7+/-2.1 mm; P<0.001), and MVTa at mid systole in all 3 planes (153+/-46 to 93+/-24 mm2, P<0.01; 140+/-47 to 88+/-23 mm2, P<0.03; and 103+/-23 to 87+/-26 mm2, P<0.03).
CONCLUSIONS: Percutaneous coronary sinus-based mitral annuloplasty reduces chronic IMR by reducing mitral annular A-P diameter and MVTa. This suggests the potential clinical application of a new nonsurgical therapeutic approach in patients with IMR.
Full text links
Trending Papers
The ten commandments of point-of-care ultrasound (POCUS).CJEM 2023 November 17
Restrictive or Liberal Transfusion Strategy in Myocardial Infarction and Anemia.New England Journal of Medicine 2023 November 12
Cushing's syndrome.Lancet 2023 November 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app