COMPARATIVE STUDY
EVALUATION STUDIES
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Optimal bedside urinalysis for the detection of proteinuria in hypertensive pregnancy: a study of diagnostic accuracy.

OBJECTIVE: To compare semi-quantitative visual and automated methods of urine testing with fully quantitative point of care urinalysis for the detection of significant proteinuria (0.3 g/24 hours) in pregnancy complicated by hypertension.

DESIGN: A prospective comparative study.

SETTING: A large teaching maternity hospital.

SAMPLE: One hundred and seventy-one pregnant women referred to the obstetric day-care unit for assessment of newly arisen hypertension.

METHODS: Early morning urine specimens were tested with four dipstick techniques (Multistix 8SG visual and automated and microalbumin/creatinine ratio visual and automated; Bayer, Elkhart, USA) as well as a fully quantitative measure of the microalbumin creatinine ratio with the DCA 2000 (a point of care assay for albumin; Bayer). These results were compared to a 24-hour urine protein measurement and measures of diagnostic accuracy/prediction are reported.

MAIN OUTCOME MEASURES: Significant proteinuria (> or =0.3 g/24 hours) measured by laboratory assay.

RESULTS: Automated dipstick urinalysis using the Clinitek 50 has significantly better predictive values for significant proteinuria (LR(+) 4.27, 95% CI 2.78 to 6.56; LR(-) 0.225, 95% CI 0.14 to 0.37) than conventional visual dipstick urinalysis (LR(+) 2.27, 95% CI 1.47 to 3.51; LR(-) 0.635, 95% CI 0.49 to 0.82). Dipstick microalbumin/creatinine ratio testing did not improve overall detection rates with automated or visual testing. Fully quantitative point of care measurement of albumin/creatinine ratio (ACR) was significantly better than any dipstick technique (LR(+) 14.6, 95% CI 6.74 to 31.8; LR(-) 0.069, 95% CI 0.030 to 0.16).

CONCLUSIONS: This study confirms that in pregnancy automated dipstick urinalysis is a more accurate screening test for the detection of proteinuria than visual testing. ACR testing can offer a significant improvement over conventional urinalysis if a fully quantitative method of detection is employed that uses pregnancy-specific thresholds. Dipstick assessment of ACR does not improve the detection rate of significant proteinuria.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app