OBJECTIVE: To report the antenatal detection rate in a consecutive series of liveborn infants with atrioventricular septal defect (AVSD).
DESIGN: Review and analysis of referrals for detailed fetal echocardiography and postnatal diagnosis of AVSD.
SETTING: Tertiary referral centre for congenital heart disease centre with data prospectively collected between 1996 to 2001.
RESULTS: 92 consecutively liveborn infants with AVSDs were identified of which 27 (29%) were detected by routine obstetric antenatal ultrasound. The antenatal diagnosis rate was worse for liveborn infants with trisomy 21 (12 of 49 (25%) v 15 of 43 (35%) chromosomally normal children) and for infants with AVSD without other structural heart disease (18 of 74 (24%) v 9 of 18 (50%) infants with associated structural heart disease).
CONCLUSION: Despite the potential ability of fetal ultrasound to detect AVSDs, the antenatal diagnosis rate is poor. This is particularly true for infants with trisomy 21 and is of importance when counselling parents with an apparently normal fetal ultrasound scan.
DESIGN: Review and analysis of referrals for detailed fetal echocardiography and postnatal diagnosis of AVSD.
SETTING: Tertiary referral centre for congenital heart disease centre with data prospectively collected between 1996 to 2001.
RESULTS: 92 consecutively liveborn infants with AVSDs were identified of which 27 (29%) were detected by routine obstetric antenatal ultrasound. The antenatal diagnosis rate was worse for liveborn infants with trisomy 21 (12 of 49 (25%) v 15 of 43 (35%) chromosomally normal children) and for infants with AVSD without other structural heart disease (18 of 74 (24%) v 9 of 18 (50%) infants with associated structural heart disease).
CONCLUSION: Despite the potential ability of fetal ultrasound to detect AVSDs, the antenatal diagnosis rate is poor. This is particularly true for infants with trisomy 21 and is of importance when counselling parents with an apparently normal fetal ultrasound scan.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app