OBJECTIVES: To compare the clearances of low molecular weight molecules using three modalities of continuous renal replacement therapy (CRRT) at the low blood flow rates typically used in pediatric patients.

DESIGN: A controlled, in vitro laboratory study.

SETTING: Research laboratory of a health sciences university.

SUBJECTS: AN69 dialysis hemofilter.

INTERVENTIONS: CRRT was performed using a 0.6 m(2) AN69 hemofilter. Human whole blood and plasma were combined to achieve a hematocrit of approximately 30%. Urea and creatinine were added to obtain concentrations of approximately 54 mmol/L of blood urea nitrogen and 1770 micromol/L of creatinine. Clearance data for urea and creatinine at a blood flow rate of 60 mL/min were generated using predilution continuous venovenous hemofiltration (CVVH), postdilution CVVH, and continuous venovenous hemodialysis (CVVHD).

MEASUREMENTS AND MAIN RESULTS: Clearance of all three modalities was compared at a replacement solution (CVVH) or dialysate (CVVHD) flow rate of 16.7% of the blood flow rate. Both postdilution CVVH and CVVHD had a urea clearance of 11.3 mL/min, which was 15% greater than the 9.8 mL/min urea clearance of predilution CVVH (p <.005). Creatinine clearance with postdilution CVVH (10.7 mL/min) was 15% greater than the 9.0 mL/min clearance produced by predilution CVVH (p < 0.01). Predilution CVVH and CVVHD were compared at a flow rate of either replacement solution (CVVH) or dialysate (CVVHD) of 33% and 50% of the blood flow rate. Postdilution CVVH was not performed at high ultrafiltration rates due to the potential problem of hemoconcentration. CVVHD clearances of urea and creatinine were statistically superior to predilution CVVH at both flow rates.

CONCLUSIONS: CVVHD was superior to predilution CVVH for clearance of urea and creatinine. Postdilution CVVH and CVVHD gave nearly equivalent clearances. At the low blood flow rates used in pediatric patients, which raise concerns about high ultrafiltration during postdilution CVVH causing excessive hemoconcentration and filter clotting, CVVHD appears to be the optimal modality for maximizing clearance of small solutes during CRRT.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app