Use of the mechanical in-exsufflator in pediatric patients with neuromuscular disease and impaired cough.
Chest 2004 April
BACKGROUND: Impaired cough secondary to weakness from neuromuscular disease (NMD) can cause serious respiratory complications, including atelectasis, pneumonia, small airway obstruction, and acidosis. The mechanical in-exsufflator (MI-E) delivers a positive-pressure insufflation followed by an expulsive exsufflation, thereby simulating a normal cough. Use of the MI-E in adults with impaired cough results in improved cough flows and enhanced airway clearance. However, only limited reports of MI-E use in children exist.
OBJECTIVE: To determine the safety, tolerance, and effectiveness of the MI-E in a pediatric population.
METHOD: Retrospective medical record review.
PARTICIPANTS: Sixty-two patients (34 male patients) observed in a pediatric pulmonary program with NMD and impaired cough in whom MI-E therapy was initiated. Median age at initiation of MI-E use was 11.3 years (range, 3 months to 28.6 years). Diagnoses included the following: Duchenne muscular dystrophy (17 patients); spinal muscular atrophy, types I and II (21 patients); myopathy (12 patients); other nonspecific NMD (12 patients). Mechanical ventilation via tracheostomy was used in 29 patients, and 25 patients used noninvasive ventilation.
RESULTS: The median duration of use was 13.4 months (range, 0.5 to 45.5 months). One infant died before using MI-E at home. Five patients chose not to continue MI-E therapy. Complications were reported in two patients, but ultimately they used the MI-E device. Chronic atelectasis resolved in four patients after beginning MI-E therapy, and five patients experienced a reduction in the frequency of pneumonias.
CONCLUSION: In 90% of our study population, the use of an MI-E was safe, well-tolerated, and effective in preventing pulmonary complications.
OBJECTIVE: To determine the safety, tolerance, and effectiveness of the MI-E in a pediatric population.
METHOD: Retrospective medical record review.
PARTICIPANTS: Sixty-two patients (34 male patients) observed in a pediatric pulmonary program with NMD and impaired cough in whom MI-E therapy was initiated. Median age at initiation of MI-E use was 11.3 years (range, 3 months to 28.6 years). Diagnoses included the following: Duchenne muscular dystrophy (17 patients); spinal muscular atrophy, types I and II (21 patients); myopathy (12 patients); other nonspecific NMD (12 patients). Mechanical ventilation via tracheostomy was used in 29 patients, and 25 patients used noninvasive ventilation.
RESULTS: The median duration of use was 13.4 months (range, 0.5 to 45.5 months). One infant died before using MI-E at home. Five patients chose not to continue MI-E therapy. Complications were reported in two patients, but ultimately they used the MI-E device. Chronic atelectasis resolved in four patients after beginning MI-E therapy, and five patients experienced a reduction in the frequency of pneumonias.
CONCLUSION: In 90% of our study population, the use of an MI-E was safe, well-tolerated, and effective in preventing pulmonary complications.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app