Clinical Trial
Journal Article
Randomized Controlled Trial
Research Support, U.S. Gov't, P.H.S.
Add like
Add dislike
Add to saved papers

Symptoms, respirator use, and pulmonary function changes among New York City firefighters responding to the World Trade Center disaster.

Chest 2004 April
CONTEXT: New York City firefighters responding to the World Trade Center (WTC) disaster on September 11, 2001, were exposed to numerous hazards. A medical screening program was conducted 3 weeks after the disaster on a sample of firefighters.

OBJECTIVES: To determine whether arrival time at the WTC and other exposure variables (including respirator use) were associated with symptoms and changes in pulmonary function (after exposure - before exposure).

DESIGN: A cross-sectional comparison of firefighters representing the following groups: (1) firefighters who arrived before/during the WTC collapse, (2) firefighters who arrived 1 to 2 days after the collapse, (3) firefighters who arrived 3 to 7 days after the collapse, and (4) unexposed firefighters.

SETTING: Fire Department of New York City (FDNY) Bureau of Health Services on October 1 to 5, 2001.

POPULATION: A stratified random sample of 362 of 398 recruited working firefighters (91%). Of these, 149 firefighters (41%) were present at the WTC collapse, 142 firefighters (39%) arrived after the collapse but within 48 h, 28 firefighters (8%) arrived 3 to 7 days after the collapse, and 43 firefighters (12%) were unexposed.

MAIN OUTCOME MEASURES: New/worsening symptoms involving the eyes, skin, respiratory system, and nose and throat (NT), and changes in spirometry from before to after exposure.

RESULTS: During the first 2 weeks at the WTC site, 19% of study firefighters reported not using a respirator; 50% reported using a respirator but only rarely. Prevalence ratios (PRs) for skin, eye, respiratory, and NT symptoms showed a dose-response pattern between exposure groups based on time of arrival at the WTC site, with PRs between 2.6 and 11.4 with 95% confidence intervals (CIs) excluding 1.0 for all but skin symptoms. For those spending > 7 days at the site, the PR for respiratory symptoms was 1.32 (95% CI, 1.13 to 1.55), compared with those who were exposed for < 7 days. Mean spirometry results before and after exposure were within normal limits. The change in spirometry findings (after exposure - before exposure) showed near-equal reductions for FVC and FEV(1). These reductions were greater than the annual reductions measured in a referent population of incumbent FDNY firefighters prior to September 11 (p or= 450 mL in FEV(1) in those arriving during the first 48 h compared to the referent (p
CONCLUSIONS: The symptoms and pulmonary function changes following exposure at the WTC demonstrate the need for improvements in respirators and their use, as well as long-term medical monitoring of rescue workers.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app