Add like
Add dislike
Add to saved papers

Copeland surface replacement arthroplasty of the shoulder in rheumatoid arthritis.

BACKGROUND: Shoulder arthroplasty with a stemmed prosthesis is a recognized treatment for rheumatoid arthritis of the shoulder. The humeral component of the Copeland cementless surface replacement arthroplasty consists of a cup for surface replacement with a short central peg for primary fixation to the bone. We hypothesized that surface replacement may offer some advantages over stemmed prostheses.

METHODS: Between 1986 and 1998, seventy-five shoulders underwent surface replacement arthroplasty (thirty-three hemiarthroplasties and forty-two total shoulder arthroplasties) for the treatment of rheumatoid arthritis. The results of these procedures were reviewed after an average duration of follow-up of 6.5 years. Patients were assessed with use of the Constant score, a patient satisfaction score, and radiographs.

RESULTS: The average Constant score was 47.9 points (age and sex-adjusted score, 71%) in the hemiarthroplasty group and 53.4 points (age and sex-adjusted score, 76%) in the total shoulder replacement group. The mean range of active flexion improved from 50 degrees in the hemiarthroplasty group and 47 degrees in the total shoulder replacement group to 101 degrees and 104 degrees, respectively. Seventy-two of the seventy-five shoulders were considered by the patients to be much better or better at the time of the review. Of the sixty-eight humeral implants that were evaluated radiographically, fifty-six (82%) showed no lucencies, eleven (16%) showed localized lucencies of <1 mm in width, and one was definitely loose. Of the thirty-nine glenoid implants that were evaluated radiographically, nineteen (49%) showed no lucencies, nineteen showed localized lucencies of <1 mm, and one was definitely loose. No lucencies were observed adjacent to the hydroxyapatite-coated implants. Thirty-nine (57%) of the sixty-eight shoulders showed some degree of superior subluxation. Three patients required a major reoperation: two required a revision because of loosening of both components, and one patient with pain at the site of a hemiarthroplasty had a revision to a total shoulder arthroplasty to provide relief.

CONCLUSIONS: The indications for this surface replacement are the same as those for the conventional stemmed prostheses, but the surface replacement has the advantage of bone preservation as well as avoidance of the potential complications associated with a long humeral stem in rheumatoid bone. This procedure is not suitable for severely damaged joints in which the humeral head is insufficient or too soft.

LEVEL OF EVIDENCE: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app