Evaluation of a triple-lumen central venous heparin-coated catheter versus a catheter coated with chlorhexidine and silver sulfadiazine in critically ill patients.

OBJECTIVE: To compare the incidence of catheter colonization and catheter-related bloodstream infections between heparin-coated catheters and those coated with a synergistic combination of chlorhexidine and silver sulfadiazine.

DESIGN: Randomized, controlled clinical trial.

SETTING: A 20-bed medical-surgical intensive care unit.

PATIENTS: A total of 180 patients requiring the insertion of a trilumen central venous catheter. INTERVENTIONS. Patients were randomized to receive either a trilumen heparin or chlorhexidine and silver sulfadiazine-coated catheter.

MEASUREMENTS: Catheter colonization was defined by a semiquantitative catheter tip culture yielding 15 or more colony-forming units or quantitative culture of 1,000 or more colony-forming units/ml. Catheter-related bloodstream infection as the isolation of the same microorganism from a peripheral blood culture and catheter tip.

RESULTS: A total of 260 catheters were cultured. Out of 132 heparin-coated catheters, 29 were colonized and out of 128 chlorhexidine and silver sulfadiazine-coated catheters, 13 were colonized ( p=0.03), relative risk RR=2.16 (1.18-3.97). This represents an incidence of 23.5 and 11.5 episodes of catheter colonization per 1,000 catheter-days, respectively ( p=0.0059), RR=2.04 (1.05-3.84). Microorganisms isolated in catheter colonization from heparin-coated catheters were gram-positive cocci 23, gram-negative bacilli 7, and Candida spp 4. In chlorhexidine and silver sulfadiazine-coated catheters were gram-positive cocci 6 and gram-negative bacilli 11 ( p=0.009). The incidence of catheter-related bloodstream infections per 1,000 catheter-days was 3.24 in heparin-coated catheters and 2.6 in chlorhexidine and silver sulfadiazine-coated catheters ( p=0.79), RR=1.22 (0.27-5.43).

CONCLUSIONS: In critically ill patients the use of trilumen central venous catheters coated with chlorhexidine and silver sulfadiazine reduced the risk of catheter colonization due to prevention of gram-positive cocci and Candida spp.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app