Lung isolation during port-access cardiac surgery: double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker.
Journal of Cardiothoracic and Vascular Anesthesia 2003 December
OBJECTIVE: The purpose of this study was to compare the use of a double-lumen endotracheal tube to a single-lumen tube combined with a bronchial blocker for lung isolation during Port-Access cardiac surgery.
DESIGN: Prospective, randomized, controlled trial.
SETTING: Tertiary care university hospital.
PARTICIPANTS: Thirty-two patients undergoing Port-Access cardiac surgery via a right minithoracotomy.
INTERVENTIONS: Patients were randomized to intubation with either a left-sided double-lumen tube (double-lumen group) or a single-lumen tube with concomitant use of a bronchial blocker (blocker group). Comparisons between groups included (1) intubation time, (2) number of laryngoscopy attempts, (3) time required for tube exchange at the end of the operation, and (4) surgical satisfaction with the lung deflation (1-5 scale: 5 = excellent).
MEASUREMENTS AND MAIN RESULTS: The initial intubation time was similar between groups (118 +/- 82 seconds, double-lumen v 144 +/- 32 seconds, blocker; p = 0.2781). An additional 105 +/- 37 seconds was needed to exchange the double-lumen tube at the end of the operation. The double-lumen group also required more laryngoscopy attempts compared with the blocker group (2.3 +/- 0.6, double-lumen v 1.1 +/- 0.4, blocker; p = 0.0001). The lung deflation was better in the double-lumen group (5 [4-5], double-lumen v 4 [3-5], blocker, p = 0.0414).
CONCLUSIONS: Compared with a single-lumen tube/bronchial blocker combination the double-lumen endotracheal tube required more laryngoscopy attempts and additional time to replace the tube at the end of the case but resulted in slightly better overall lung deflation.
DESIGN: Prospective, randomized, controlled trial.
SETTING: Tertiary care university hospital.
PARTICIPANTS: Thirty-two patients undergoing Port-Access cardiac surgery via a right minithoracotomy.
INTERVENTIONS: Patients were randomized to intubation with either a left-sided double-lumen tube (double-lumen group) or a single-lumen tube with concomitant use of a bronchial blocker (blocker group). Comparisons between groups included (1) intubation time, (2) number of laryngoscopy attempts, (3) time required for tube exchange at the end of the operation, and (4) surgical satisfaction with the lung deflation (1-5 scale: 5 = excellent).
MEASUREMENTS AND MAIN RESULTS: The initial intubation time was similar between groups (118 +/- 82 seconds, double-lumen v 144 +/- 32 seconds, blocker; p = 0.2781). An additional 105 +/- 37 seconds was needed to exchange the double-lumen tube at the end of the operation. The double-lumen group also required more laryngoscopy attempts compared with the blocker group (2.3 +/- 0.6, double-lumen v 1.1 +/- 0.4, blocker; p = 0.0001). The lung deflation was better in the double-lumen group (5 [4-5], double-lumen v 4 [3-5], blocker, p = 0.0414).
CONCLUSIONS: Compared with a single-lumen tube/bronchial blocker combination the double-lumen endotracheal tube required more laryngoscopy attempts and additional time to replace the tube at the end of the case but resulted in slightly better overall lung deflation.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app