AIM: To investigate the possible changes in the renal tubular function in severe short-term hypothyroidism using (99m)Tc-MAG(3) renography.
METHODS: 27 consecutive thyroidectomized patients (7 males and 20 females) aged 19-79 (mean 53) years were included in the present study. (99m)Tc-MAG(3) renography was performed in all patients before and after thyroid hormone replacement therapy. In addition, (51)Cr-EDTA clearance and serum creatinine concentrations were determined.
RESULTS: The serum creatinine concentrations were significantly increased in hypothyroidism as compared with the concentrations after thyroxine substitution (1.30 +/- 0.44 vs. 1.04 +/- 0.32 mg/dl, p < 0.05). According to the (51)Cr-EDTA clearance, the glomerular filtration rate was significantly lower in hypothyroidism than after treatment (61 +/- 18 vs. 75 +/- 23 ml/min). In contrast, we did not find any significant change in the renographic parameters for (99m)Tc-MAG(3) before and after treatment (total excreted activity 20 min after administration 51 +/- 12 vs. 54 +/- 14%; T(max) left:right 4.2 +/- 1.77 : 3.91 +/- 1.06 min vs. 4.1 +/- 1.66 : 4.4 +/- 1.96 min).
CONCLUSIONS: We did not find any influence of thyroid hormones on the outcome of (99m )Tc-MAG(3) renography. As (99m)Tc-MAG(3) reflects the tubular function, it seems that the renal hemodynamic changes in severe hypothyroidism mainly affect the glomerular function. In general, the glomerular filtration rate reduction seems to be reversible after hormone substitution therapy; however, care has to be taken in patients with renal insufficiency.
METHODS: 27 consecutive thyroidectomized patients (7 males and 20 females) aged 19-79 (mean 53) years were included in the present study. (99m)Tc-MAG(3) renography was performed in all patients before and after thyroid hormone replacement therapy. In addition, (51)Cr-EDTA clearance and serum creatinine concentrations were determined.
RESULTS: The serum creatinine concentrations were significantly increased in hypothyroidism as compared with the concentrations after thyroxine substitution (1.30 +/- 0.44 vs. 1.04 +/- 0.32 mg/dl, p < 0.05). According to the (51)Cr-EDTA clearance, the glomerular filtration rate was significantly lower in hypothyroidism than after treatment (61 +/- 18 vs. 75 +/- 23 ml/min). In contrast, we did not find any significant change in the renographic parameters for (99m)Tc-MAG(3) before and after treatment (total excreted activity 20 min after administration 51 +/- 12 vs. 54 +/- 14%; T(max) left:right 4.2 +/- 1.77 : 3.91 +/- 1.06 min vs. 4.1 +/- 1.66 : 4.4 +/- 1.96 min).
CONCLUSIONS: We did not find any influence of thyroid hormones on the outcome of (99m )Tc-MAG(3) renography. As (99m)Tc-MAG(3) reflects the tubular function, it seems that the renal hemodynamic changes in severe hypothyroidism mainly affect the glomerular function. In general, the glomerular filtration rate reduction seems to be reversible after hormone substitution therapy; however, care has to be taken in patients with renal insufficiency.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app