Extubation failure in pediatric intensive care: a multiple-center study of risk factors and outcomes.

OBJECTIVE: To determine a contemporary failed extubation rate, risk factors, and consequences of extubation failure in pediatric intensive care units (PICUs). Three hypotheses were investigated: a) Extubation failure is in part disease specific; b) preexisting respiratory conditions predispose to extubation failure; and c) admission acuity scoring does not affect extubation failure.

DESIGN: Twelve-month prospective, observational, clinical study.

SETTING: Sixteen diverse PICUs in the United States.

PATIENTS: Patients were 2,794 patients from the newborn period to 18 yrs of age experiencing a planned extubation trial.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: A descriptive statistical analysis was performed, and outcome differences of the failed extubation population were determined. The extubation failure rate was 6.2% (174 of 2,794; 95% confidence interval, 5.3-7.1). Patient features associated with extubation failure (p <.05) included age < or =24 months; dysgenetic condition; syndromic condition; chronic respiratory disorder; chronic neurologic condition; medical or surgical airway condition; chronic noninvasive positive pressure ventilation; the need to replace the endotracheal tube on admission to the PICU; and the use of racemic epinephrine, steroids, helium-oxygen therapy (heliox), or noninvasive positive pressure ventilation within 24 hrs of extubation. Patients failing extubation had longer pre-extubation intubation time (failed, 148.7 hrs, SD +/- 207.8 vs. success, 107.9 hrs, SD +/- 171.3; p <.001), longer PICU length of stay (17.5 days, SD +/- 15.6 vs. 7.6 days, SD +/- 11.1; p <.001), and a higher mortality rate than patients not failing extubation (4.0% vs. 0.8%; p <.001). Failure was found to be in part disease specific, and preexisting respiratory conditions were found to predispose to failure whereas admission acuity did not.

CONCLUSION: A variety of patient features are associated with an increase in extubation failure rate, and serious outcome consequences characterize the extubation failure population in PICUs.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app