We have located links that may give you full text access.
Chronic lithium nephropathy: MR imaging for diagnosis.
Radiology 2003 November
PURPOSE: To evaluate the appearance of lithium nephropathy at magnetic resonance (MR) imaging.
MATERIALS AND METHODS: Sixteen patients with renal insufficiency and clinical and laboratory evidence of nephropathy secondary to therapy with lithium salts were examined with a 1.5-T MR imaging unit with T1-weighted, T2-weighted fast imaging with steady-state precession (true FISP), rapid acquisition with relaxation enhancement, half-Fourier turbo spin-echo, and gadolinium-enhanced (FISP three-dimensional MR angiographic) sequences. Renal size and the presence, number, location and size of parenchymal cysts were analyzed. The cysts in each kidney were defined as rare (fewer than 10 cysts), sparse (between 10 and 30 cysts), abundant (30-60 cysts), or very abundant (more than 60 cysts).
RESULTS: The mean length of both kidneys was 104 mm +/- 9 in seven cases, and one or both kidneys were less than 90 mm in length in nine cases. Renal microcysts measuring from 1 to 2 mm were detected in all patients. They were either very abundant (n = 12), abundant (n = 2), or sparse (n = 2). The cysts were located with equal abundance in both the cortex and the medulla in 11 cases and were predominantly located in the renal cortex in five cases. No renal artery stenosis was present.
CONCLUSION: Microcysts secondary to long-term lithium therapy can be detected with MR imaging.
MATERIALS AND METHODS: Sixteen patients with renal insufficiency and clinical and laboratory evidence of nephropathy secondary to therapy with lithium salts were examined with a 1.5-T MR imaging unit with T1-weighted, T2-weighted fast imaging with steady-state precession (true FISP), rapid acquisition with relaxation enhancement, half-Fourier turbo spin-echo, and gadolinium-enhanced (FISP three-dimensional MR angiographic) sequences. Renal size and the presence, number, location and size of parenchymal cysts were analyzed. The cysts in each kidney were defined as rare (fewer than 10 cysts), sparse (between 10 and 30 cysts), abundant (30-60 cysts), or very abundant (more than 60 cysts).
RESULTS: The mean length of both kidneys was 104 mm +/- 9 in seven cases, and one or both kidneys were less than 90 mm in length in nine cases. Renal microcysts measuring from 1 to 2 mm were detected in all patients. They were either very abundant (n = 12), abundant (n = 2), or sparse (n = 2). The cysts were located with equal abundance in both the cortex and the medulla in 11 cases and were predominantly located in the renal cortex in five cases. No renal artery stenosis was present.
CONCLUSION: Microcysts secondary to long-term lithium therapy can be detected with MR imaging.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app