REVIEW
Transcatheter closure of patent foramen ovale after presumed paradoxical embolism.
Circulation 1992 December
BACKGROUND: Many have proposed a relation between presence of a patent foramen ovale, with or without atrial septal aneurysm, and cryptogenic stroke. The effect of foramen ovale closure on the risk for subsequent strokes is unknown.
METHODS AND RESULTS: Transcatheter closure of a patent foramen ovale was undertaken in 36 patients with known right-to-left atrial shunting and presumed paradoxical emboli (31 strokes, 25 transient neurological events, four systemic arterial emboli, and two brain abscesses). Individual patients had between one and four such events. None had a left heart or carotid source of embolism; 31 of 35 had no known risk factors for stroke. Events occurred in 12 patients while they were taking warfarin. At cardiac catheterization, patent foramina ovalia were significantly larger than predicted for age in 67% of the patients. Implantation of a double-umbrella device in the patent foramen ovale was achieved in all without serious procedural complications. Of 34 who have returned for follow-up, one has a residual atrial communication that may be clinically important, five had trivial leaks, and 28 have complete closure. There have been no strokes during a mean follow-up of 8.4 months.
CONCLUSIONS: Transcatheter closure of a patent foramen ovale can be accomplished with little morbidity and may reduce the risk of recurrence. Further investigations directed toward identifying the population at risk and assessing the effect of intervention are warranted.
METHODS AND RESULTS: Transcatheter closure of a patent foramen ovale was undertaken in 36 patients with known right-to-left atrial shunting and presumed paradoxical emboli (31 strokes, 25 transient neurological events, four systemic arterial emboli, and two brain abscesses). Individual patients had between one and four such events. None had a left heart or carotid source of embolism; 31 of 35 had no known risk factors for stroke. Events occurred in 12 patients while they were taking warfarin. At cardiac catheterization, patent foramina ovalia were significantly larger than predicted for age in 67% of the patients. Implantation of a double-umbrella device in the patent foramen ovale was achieved in all without serious procedural complications. Of 34 who have returned for follow-up, one has a residual atrial communication that may be clinically important, five had trivial leaks, and 28 have complete closure. There have been no strokes during a mean follow-up of 8.4 months.
CONCLUSIONS: Transcatheter closure of a patent foramen ovale can be accomplished with little morbidity and may reduce the risk of recurrence. Further investigations directed toward identifying the population at risk and assessing the effect of intervention are warranted.
Full text links
Trending Papers
Oral Anticoagulation in Patients with Chronic Liver Disease.Medicina 2023 Februrary 13
Helicobacter pylori Infection: Current Status and Future Prospects on Diagnostic, Therapeutic and Control Challenges.Antibiotics 2023 January 18
Glucagon-Like Peptide 1 Receptor Agonists Versus Sodium-Glucose Cotransporter 2 Inhibitors for Atherosclerotic Cardiovascular Disease in Patients With Type 2 Diabetes.Cardiology Research 2023 Februrary
Physical interventions to interrupt or reduce the spread of respiratory viruses.Cochrane Database of Systematic Reviews 2023 January 31
Fluid Resuscitation in Patients with Cirrhosis and Sepsis: A Multidisciplinary Perspective.Journal of Hepatology 2023 March 2
Evaluation and Management of Pulmonary Hypertension in Noncardiac Surgery: A Scientific Statement From the American Heart Association.Circulation 2023 March 17
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app