JOURNAL ARTICLE
[CT-guided aortic balloon occlusion in traumatic abdominal and pelvic bleeding].
PURPOSE: To introduce a new interventional method for CT-guided aortic balloon occlusion in patients with life-threatening abdominal or pelvic bleeding.
MATERIALS AND METHODS: Three male patients (age 18, 30, and 45 years) with multiple trauma underwent CT-guided balloon occlusion of the aorta after CT identified an active abdominal or pelvic bleeding site and the patients became unstable (systolic blood pressure, BP < 80 mm Hg) despite resuscitation continuous volume. Using a right femoral approach, a 9F sheath was immediately introduced and the positions of the guide wire and balloon catheter (20 x 40 mm) were intermittently checked with CT scans and CT fluoroscopy. In one case, a C-clamp was applied to the pelvic ring under CT guidance for emergency stabilization of an unstable pelvic fracture.
RESULTS: CT-guided aortic balloon occlusion and the mounting of the pelvic C-clamp were technically successful. Intervention time was 4 to 6 minutes for aortic balloon occlusion. All patients became at least temporarily stable hemodynamically with the blood pressure rising above 100 mmHg. The infrarenal occlusion catheters were left in place up to 60 minutes. Suprarenal occlusion was not performed. Two patients died due to protracted shock and complex injuries (injury severity score (ISS: 50 - 64).
CONCLUSION: CT-guided aortic occlusion provides fast and effective bleeding control immediately after completion of the diagnostic CT. The procedure can be combined with other specific emergency surgical or interventional procedures. Experience with more patients is necessary for further evaluation of this new technique.
MATERIALS AND METHODS: Three male patients (age 18, 30, and 45 years) with multiple trauma underwent CT-guided balloon occlusion of the aorta after CT identified an active abdominal or pelvic bleeding site and the patients became unstable (systolic blood pressure, BP < 80 mm Hg) despite resuscitation continuous volume. Using a right femoral approach, a 9F sheath was immediately introduced and the positions of the guide wire and balloon catheter (20 x 40 mm) were intermittently checked with CT scans and CT fluoroscopy. In one case, a C-clamp was applied to the pelvic ring under CT guidance for emergency stabilization of an unstable pelvic fracture.
RESULTS: CT-guided aortic balloon occlusion and the mounting of the pelvic C-clamp were technically successful. Intervention time was 4 to 6 minutes for aortic balloon occlusion. All patients became at least temporarily stable hemodynamically with the blood pressure rising above 100 mmHg. The infrarenal occlusion catheters were left in place up to 60 minutes. Suprarenal occlusion was not performed. Two patients died due to protracted shock and complex injuries (injury severity score (ISS: 50 - 64).
CONCLUSION: CT-guided aortic occlusion provides fast and effective bleeding control immediately after completion of the diagnostic CT. The procedure can be combined with other specific emergency surgical or interventional procedures. Experience with more patients is necessary for further evaluation of this new technique.
Full text links
Trending Papers
Migraine.Annals of Internal Medicine 2023 January 11
How to diagnose iron deficiency in chronic disease: A review of current methods and potential marker for the outcome.European Journal of Medical Research 2023 January 10
Long COVID: major findings, mechanisms and recommendations.Nature Reviews. Microbiology 2023 January 14
Diabetic kidney disease in type 2 diabetes: a consensus statement from the Swiss Societies of Diabetes and Nephrology.Swiss Medical Weekly 2023 January 7
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app