We have located links that may give you full text access.
Effects of extensor pollicis longus transposition and extensor indicis proprius transfer to extensor pollicis longus on thumb mechanics.
Journal of Hand Surgery 2003 July
PURPOSE: The spatial relationship of the extensor pollicis longus (EPL) to the thumb carpometacarpal (CMC) joint may be altered by its transposition from the third dorsal wrist compartment and by subcutaneous extensor indicis proprius (EIP) to EPL tendon transfer. Changes in tendon position could alter thumb function. This study examined changes in the EPL adduction moment arm after EPL tendon transposition from its extensor compartment or EIP transfer.
METHODS: The EPL adduction moment arm at the thumb carpometacarpal joint was determined under 4 tendon conditions: (1) intact extensor pollicis longus, (2) transposed extensor pollicis longus, (3) extensor indicis proprius to extensor pollicis longus tendon transfer through an extensor retinacular pulley, and (4) extensor indicis proprius tendon transfer through a subcutaneous route. Each tendon condition was tested in 2 wrist positions: neutral and 40 degrees of flexion.
RESULTS: The wrist neutral/flexion moment arms for the 4 tendon conditions, in millimeters, were 9.2/7.3, 3.6/1.2, 8.3/5.1, and 4.8/1.0.
CONCLUSIONS: EPL transposition produces a significant decrease of its adduction moment arm at the thumb CMC joint, an effect exacerbated by wrist flexion. The moment arm mechanics of the pulley and subcutaneous EIP tendon transfer resemble those of the intact and transposed EPL, respectively. Diminution of the adduction moment arm could impair thumb function, especially adduction.
METHODS: The EPL adduction moment arm at the thumb carpometacarpal joint was determined under 4 tendon conditions: (1) intact extensor pollicis longus, (2) transposed extensor pollicis longus, (3) extensor indicis proprius to extensor pollicis longus tendon transfer through an extensor retinacular pulley, and (4) extensor indicis proprius tendon transfer through a subcutaneous route. Each tendon condition was tested in 2 wrist positions: neutral and 40 degrees of flexion.
RESULTS: The wrist neutral/flexion moment arms for the 4 tendon conditions, in millimeters, were 9.2/7.3, 3.6/1.2, 8.3/5.1, and 4.8/1.0.
CONCLUSIONS: EPL transposition produces a significant decrease of its adduction moment arm at the thumb CMC joint, an effect exacerbated by wrist flexion. The moment arm mechanics of the pulley and subcutaneous EIP tendon transfer resemble those of the intact and transposed EPL, respectively. Diminution of the adduction moment arm could impair thumb function, especially adduction.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app