We have located links that may give you full text access.
EVALUATION STUDIES
JOURNAL ARTICLE
Predictability of intrapartum and neonatal outcomes with the amniotic fluid volume distribution: a reassessment using the amniotic fluid index, single deepest pocket, and a dye-determined amniotic fluid volume.
OBJECTIVE: The purpose of this study was to establish whether ultrasound-estimated or dye-determined amniotic fluid distribution (upper compared with lower quadrant) is predictive of perinatal outcome.
STUDY DESIGN: Amniotic fluid distribution as measured by the amniotic fluid index, single deepest pocket, and dye-determined volumes was ascertained and correlated with intrapartum and neonatal outcomes.
RESULTS: Between January 1997 and January 2001, 135 women (70 upper-greater and 65 lower-greater) participated in this prospective observational study. The sum of the amniotic fluid index (P =.309), single deepest pocket (P =.168), and dye-determined amniotic fluid volume (P =.368) for the upper-greater compared with the lower-greater groups were similar. Decelerations in labor (P =.597), late decelerations (P =.999), cesarean deliveries for fetal distress (P =.413), and umbilical cord pH < 7.2 were similar (P =.647)
CONCLUSION: Ultrasound-estimated and dye-determined amniotic fluid volumes are similar between upper-greater and lower-greater groups, and intrapartum/neonatal outcomes are not affected by the amniotic fluid distribution.
STUDY DESIGN: Amniotic fluid distribution as measured by the amniotic fluid index, single deepest pocket, and dye-determined volumes was ascertained and correlated with intrapartum and neonatal outcomes.
RESULTS: Between January 1997 and January 2001, 135 women (70 upper-greater and 65 lower-greater) participated in this prospective observational study. The sum of the amniotic fluid index (P =.309), single deepest pocket (P =.168), and dye-determined amniotic fluid volume (P =.368) for the upper-greater compared with the lower-greater groups were similar. Decelerations in labor (P =.597), late decelerations (P =.999), cesarean deliveries for fetal distress (P =.413), and umbilical cord pH < 7.2 were similar (P =.647)
CONCLUSION: Ultrasound-estimated and dye-determined amniotic fluid volumes are similar between upper-greater and lower-greater groups, and intrapartum/neonatal outcomes are not affected by the amniotic fluid distribution.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app