We have located links that may give you full text access.
Evaluation of the deep venous system in patients with suspected pulmonary embolism with multi-detector CT: a prospective study in comparison to Doppler sonography.
OBJECTIVE: This prospective study was done to evaluate the ability of indirect multidetector row CT venography (CTV) in detecting deep venous thrombosis of the pelvis and the thighs in comparison with Doppler sonography in patients with suspected pulmonary embolism (PE).
METHODS: Forty-one patients with suspected PE were included, and CTV (collimation 4 x 2.5 mm, table feed 12.5 mm, 120 kV, eff. mAs 165) from the iliac crest to the knees was done after CT angiography (CTA) of the pulmonary arteries. Doppler sonography was performed within 24 hours. Applied radiation doses were estimated using the PC program WinDose.
RESULTS: PE was diagnosed in 20 patients with additional DVT in 11 patients. The CTV has a sensitivity of 100%, specificity of 96.6%, a positive and negative predictive value of 91.7% and 100%, respectively. The median cumulative effective dose for CTV was 8.26 mSv with a gonadal dose of 3.87 mSv. Changing the CTV protocol to a collimation of 4 x 5 mm with a 25 mm table feed could reduce the dose by approximately 11% (p < 0.05) to 7.25 mSv and 3.35 mSv, respectively.
CONCLUSION: CTV is a safe and quick diagnostic tool for detecting DVT in patients with suspected PE. Due to the relevant increase in radiation dose, the indication has to be considered very carefully.
METHODS: Forty-one patients with suspected PE were included, and CTV (collimation 4 x 2.5 mm, table feed 12.5 mm, 120 kV, eff. mAs 165) from the iliac crest to the knees was done after CT angiography (CTA) of the pulmonary arteries. Doppler sonography was performed within 24 hours. Applied radiation doses were estimated using the PC program WinDose.
RESULTS: PE was diagnosed in 20 patients with additional DVT in 11 patients. The CTV has a sensitivity of 100%, specificity of 96.6%, a positive and negative predictive value of 91.7% and 100%, respectively. The median cumulative effective dose for CTV was 8.26 mSv with a gonadal dose of 3.87 mSv. Changing the CTV protocol to a collimation of 4 x 5 mm with a 25 mm table feed could reduce the dose by approximately 11% (p < 0.05) to 7.25 mSv and 3.35 mSv, respectively.
CONCLUSION: CTV is a safe and quick diagnostic tool for detecting DVT in patients with suspected PE. Due to the relevant increase in radiation dose, the indication has to be considered very carefully.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app