We have located links that may give you full text access.
Comparative Study
Journal Article
Antibodies to human recombinant tissue transglutaminase may detect coeliac disease patients undiagnosed by endomysial antibodies.
Alimentary Pharmacology & Therapeutics 2003 June 2
BACKGROUND: The screening and diagnosis of coeliac disease have been simplified by the advent of new serological tools.
AIM: To assess the clinical utility of a newly developed kit for antibodies to human recombinant tissue transglutaminase (hu-anti-tTG) in a large population of patients undergoing intestinal biopsy for suspected intestinal disorders.
METHODS: We evaluated 426 serum samples from consecutive adult patients (250 from untreated coeliac disease patients and 176 from individuals in whom a diagnosis of coeliac disease had been excluded), obtained at the time of intestinal biopsy. Samples were tested for immunoglobulin A (IgA) hu-anti-tTG by enzyme-linked immunoabsorbent assay, IgA endomysial antibodies (EmA) by indirect immunofluorescence and IgA and IgG antigliadin antibodies by enzyme-linked immunoabsorbent assay. A sub-group of samples was also assessed for a guinea-pig-based anti-tissue transglutaminase.
RESULTS: According to the cut-off for hu-anti-tTG, the sensitivity, specificity and positive and negative predictive values were 91%, 96%, 97% and 87%, respectively. Simultaneous determination of EmA showed values of 86%, 100%, 100% and 83% for the same parameters. Although 19 coeliac disease patients (7.6%) were negative for EmA and hu-anti-tTG, both tests rendered superior statistical values to antigliadin antibody tests. At diagnosis, IgA deficiency was detected in 11 patients, but both assays were able to detect samples with mild to moderate deficiency. The comparison of hu-anti-tTG with EmA showed excellent concordance between the tests (kappa statistic, 0.85). Discordance was observed in 20 samples from coeliac disease patients (8%) and in nine samples from controls (5%). Fifteen samples had an EmA-negative but hu-anti-tTG-positive serology, and five showed the converse pattern. Comparison of human recombinant and guinea-pig tests showed concordant results in 96% of cases.
CONCLUSIONS: The quantitative determination of hu-anti-tTG type IgA using a commercial enzyme-linked immunoabsorbent assay kit was highly sensitive and specific for the detection of coeliac disease. Our results in a large population of patients with a clinical condition suggestive of the disorder demonstrated that the test can be used to detect a substantial number of patients otherwise unrecognized by IgA EmA.
AIM: To assess the clinical utility of a newly developed kit for antibodies to human recombinant tissue transglutaminase (hu-anti-tTG) in a large population of patients undergoing intestinal biopsy for suspected intestinal disorders.
METHODS: We evaluated 426 serum samples from consecutive adult patients (250 from untreated coeliac disease patients and 176 from individuals in whom a diagnosis of coeliac disease had been excluded), obtained at the time of intestinal biopsy. Samples were tested for immunoglobulin A (IgA) hu-anti-tTG by enzyme-linked immunoabsorbent assay, IgA endomysial antibodies (EmA) by indirect immunofluorescence and IgA and IgG antigliadin antibodies by enzyme-linked immunoabsorbent assay. A sub-group of samples was also assessed for a guinea-pig-based anti-tissue transglutaminase.
RESULTS: According to the cut-off for hu-anti-tTG, the sensitivity, specificity and positive and negative predictive values were 91%, 96%, 97% and 87%, respectively. Simultaneous determination of EmA showed values of 86%, 100%, 100% and 83% for the same parameters. Although 19 coeliac disease patients (7.6%) were negative for EmA and hu-anti-tTG, both tests rendered superior statistical values to antigliadin antibody tests. At diagnosis, IgA deficiency was detected in 11 patients, but both assays were able to detect samples with mild to moderate deficiency. The comparison of hu-anti-tTG with EmA showed excellent concordance between the tests (kappa statistic, 0.85). Discordance was observed in 20 samples from coeliac disease patients (8%) and in nine samples from controls (5%). Fifteen samples had an EmA-negative but hu-anti-tTG-positive serology, and five showed the converse pattern. Comparison of human recombinant and guinea-pig tests showed concordant results in 96% of cases.
CONCLUSIONS: The quantitative determination of hu-anti-tTG type IgA using a commercial enzyme-linked immunoabsorbent assay kit was highly sensitive and specific for the detection of coeliac disease. Our results in a large population of patients with a clinical condition suggestive of the disorder demonstrated that the test can be used to detect a substantial number of patients otherwise unrecognized by IgA EmA.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app