Time course of expiratory flow limitation in COPD patients during acute respiratory failure requiring mechanical ventilation.

Chest 2003 May
STUDY OBJECTIVES: (1) To determine the incidence of expiratory flow limitation (FL) at ICU admission, at the time of extubation, and at ICU discharge in intubated patients with COPD receiving mechanical ventilation for acute respiratory failure (ARF); and (2) to assess the feasibility of inspiratory capacity (IC) as an indication of pulmonary dynamic hyperinflation in this setting.

DESIGN: Prospective, observational pilot study with physiologic measurements performed at ICU admission and during the weaning process driven by the clinician. A 60-min T-tube trial was initiated once criteria for weaning were present. The decision to extubate or reventilate patients was made by the clinician at the end of this session. Assessment of failure or success of T-tube trials was performed independently.

SETTING: A 25-bed ICU of a tertiary teaching university hospital.

PATIENTS: Over a 13-month period, 25 intubated patients with COPD receiving mechanical ventilation for ARF were included.

INTERVENTIONS: None.

MEASUREMENTS AND RESULTS: At ICU admission, FL assessed by the negative expiratory pressure test was measured under passive ventilatory conditions at the baseline ventilatory settings, on zero end-expiratory pressure, and in a semirecumbent position. During weaning, FL, respiratory pattern, and IC were measured during T-tube trials, before extubation, 1 h after extubation, and at ICU discharge. At ICU admission, 24 of 25 patients presented FL with, on average, 73 +/- 22% of the tidal volume. Ten patients were unavailable for follow-up due to death (n = 6) unplanned extubation (n = 3), or refusal (n = 1), so that only 15 patients completed the whole protocol (all 15 patients were extubated). For these 15 patients, the incidence of FL was 93% at ICU admission, 47% before extubation, and 40% at ICU discharge. IC was significantly greater at ICU discharge than before extubation (36 +/- 11% predicted vs 44 +/- 12% predicted, p < 0.01) and in successful T-tube trials compared with unsuccessful T-tube trials (38 +/- 13% predicted vs 24 +/- 8% predicted, p < 0.01).

CONCLUSIONS: The incidence of expiratory FL is high in patients with COPD receiving mechanical ventilation, and is reduced during aggressive therapy when the patient is placed on mechanical ventilatory support and the time that weaning begins during the ICU stay. IC was lower in patients in whom weaning was unsuccessful. Further large-scale studies are required to confirm these preliminary results.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app