JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Detection of subclinical infection in significant breast implant capsules.

The pathogenesis of fibrous capsular contracture after augmentation mammaplasty is still debated. One hypothesis implicates low-grade bacterial infections as a cause. The presence of a staphylococcal biofilm in a patient with recurrent capsular contracture was previously reported. A comparative, prospective, blinded, clinical study of implants and capsules removed from patients with or without significant capsular contracture was conducted to investigate the association of biofilm contamination, breast implants, and capsular contracture. Capsule and implant samples obtained during explantation were tested by routine microbiological culture, sensitive broth culture (after maceration and sonication), and scanning electron microscopy. Clinical parameters were correlated with microbiological findings. A total of 48 implant and/or capsule samples were obtained from 27 breasts during a 22-month period. Of the 27 breasts, 19 exhibited significant contracture (Baker grade III/IV). The mean duration of implantation was 9.2 years (range, 0.4 to 26.0 years). Routine swab cultures obtained at the time of explantation were negative for bacterial growth for all samples. The sensitive broth culture technique yielded 24 positive samples (50 percent, n = 48). An analysis of capsules demonstrated that 17 of 19 samples obtained from patients with significant contracture were positive, compared with only one of eight samples obtained from patients with minimal or no contracture (p = 0.0006). Fourteen of the 17 positive cultures from significantly contracted breasts yielded coagulase-negative staphylococci, mainly, species of the Staphylococcus epidermidis group. The presence of coagulase-negative staphylococci was also significantly associated with capsular contracture (p = 0.01). There was no significant difference in the frequency of culture positivity for saline versus silicone implants (p = 0.885). Scanning electron microscopy confirmed the presence of extensive biofilm on implants and within capsules.Biofilm, in particular, S. epidermidis biofilm, was detected for a significant proportion of patients with capsular contracture. This implicates biofilm disease in the pathogenesis of contracture, and strategies for its prevention should be explored.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app