Clinical Trial
Comparative Study
Evaluation Studies
Journal Article
Add like
Add dislike
Add to saved papers

A comparison of the PAxpress and face mask plus Guedel airway by inexperienced personnel after mannequin-only training.

UNLABELLED: The PAxpress (PAX) is a new extraglottic airway device consisting of an anatomically curved tube, an inflatable circular cuff in the midsection, a noninflatable gilled conical cuff at the distal end, and an anterior-facing, rectangular hooded vent between the two cuffs. We compared the ability of nurses with no previous airway management experience to ventilate the lungs of 45 ASA physical status I and II anesthetized, paralyzed patients using either the PAX or face mask and Guedel airway (FM/GA) after mannequin-only training. Nurses were asked to ventilate the patient to an expired target tidal volume of 7 mL/kg and then to the maximum tidal volume achievable. The FM/GA was used first and the then the PAX. The target tidal volume was achieved in all patients with both devices. There were no differences in the time taken (PAX, 41 +/- 15 s; FM/GA, 39 +/- 25 s) or the number of insertion attempts to achieve the target tidal volume. There were no differences in the frequency of esophageal leaks at the target (PAX, 9%; FM/GA, 4%) and maximum tidal volume (PAX, 51%; FM/GA, 49%). The maximal tidal volume (1261 +/- 306 versus 958 +/- 220 mL; P < 0.0001) and peak airway pressure (37 +/- 5 versus 28 +/- 6 cm H(2)O; P < 0.0001) was larger for the PAX, but blood was detected more frequently (22% versus 0%; P = 0.001). We conclude that ventilation to a target tidal volume of 7 mL/kg in anesthetized, paralyzed adults is equally successful for the PAX and FM/GA by inexperienced nurses after mannequin-only training. However, the maximal tidal volume and peak airway pressure is larger and airway trauma more common with the PAX.

IMPLICATIONS: Ventilation to a target tidal volume of 7 mL/kg in anesthetized, paralyzed adults is equally successful for the PAxpress (PAX) and Face Mask/Guedel Airway by inexperienced nurses after mannequin-only training. However, the maximal tidal volume and peak airway pressure is larger and airway trauma more common with the PAX.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app