Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays.

STATEMENT OF PROBLEM: The accuracy of an implant fixture-level impression is affected by the type of impression tray used.

PURPOSE: The purpose of this in vitro study was to investigate the accuracy of open tray implant impressions comparing polycarbonate stock impression trays and rigid custom-made impression trays to make implant fixture-level impressions.

MATERIAL AND METHODS: Gold cylinder pairs, splinted by gold bars (reference frameworks) were constructed on an aluminum typodont. Polyether impressions were made of 2 pairs of Brånemark 3.75-mm diameter fixtures mounted in an aluminium typodont, with 3 stock impression trays, 3 close-fit custom trays, and 3 spaced custom impression trays, by use of an open tray technique. The casts produced were assessed for accuracy by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of these reference frameworks to the analogs within the working cast using a traveling microscope. Comparison of gap dimensions by tray type was performed with a nonparametric Kruskal-Wallis analysis of variance (ANOVA) followed by pair-wise Mann-Whitney U tests. To adjust for multiple comparisons in the post-ANOVA contrasts (P<.02). Comparison of gap dimensions between anterior and posterior regions were performed with Mann-Whitney U tests (P <.05).

RESULTS: The results showed that the mean fit accuracy, as measured by vertical fit discrepancy, of casts from the stock trays (23 +/- 20 microm) were statistically significantly less (P<.001) than the spaced custom trays (12 +/- 10 microm) or close fit custom trays (11 +/- 10 microm). The difference in median gap size for analogs with a 20-mm separation was 10 microm.

CONCLUSION: Within the limits of this in vitro study, rigid custom trays produced significantly more accurate impressions than the polycarbonate stock trays. The stock trays used in this study could not produce accurate impressions consistently. For analogs with a 20-mm separation, there was a difference in medians of 10 microm in accuracy between the stock and custom trays.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app