We have located links that may give you full text access.
JOURNAL ARTICLE
REVIEW
3-D imaging with MDCT.
European Journal of Radiology 2003 March
Without doubt, the greatest challenge of multidetector-row CT is dealing with 'data explosion'. For our carotid/intracranial CT angiograms, we routinely have 375 images to review (300 mm coverage reconstructed every 0.8 mm); for aortic studies we have 450-500 images ( approximately 600 mm coverage reconstructed every 1.3 mm); and for a study of the lower extremity inflow and run-off, we may generate 900-1000 transverse reconstructions. While we could reconstruct fewer images for these data, experience with single-detector row CT scanners indicates that longitudinal resolution and disease detection is improved when at least 50% overlap of cross-sections is generated [Radiology 200 (1996) 312]. If we are to optimize our clinical protocols and take full advantage of these CT scanners, we will need to change the way that we interpret, transfer, and store CT data. Film is no longer a viable option. Workstation based review of transverse reconstructions for interpretation is a necessity, but the workstations must improve to provide efficient access to these data, and we must have a way of providing our clinicians with images that can be transported to clinics and the operating room. Alternative visualization and analysis using volumetric tools, including 3-D visualization must evolve from luxury to necessity. We cannot rest on historical precedent to interpret these near isotropically sampled volumetric data using transverse reconstructions alone [Radiology 173 (1989) 527]. Although the tools for volumetric analysis on 3-D workstations have evolved over recent years, they have probably not yet evolved to a level that routine interpretation can be performed as efficiently and accurately as transverse section review. Both hardware and software developments must occur. While current computer workstations and visualization software are certainly adequate for assessing these MDCT data volumetrically, the process is very time consuming. What follows are a description of current workstation capabilities and a brief discussion of where development needs to go to facilitate the complete integration of volumetric analysis into the interpretive process of CT data.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app