Optimizing bag-valve-mask ventilation with a new mouth-to-bag resuscitator

Horst G Wagner-Berger, Volker Wenzel, Angelika Stallinger, Wolfgang G Voelckel, Klaus Rheinberger, Sven Augenstein, Holger Herff, Ahamed H Idris, Volker Dörges, Karl H Lindner, Christoph Hörmann
Resuscitation 2003, 56 (2): 191-8
12589994
When ventilating an unintubated patient with a self-inflating bag, high peak inspiratory flow rates may result in high peak airway pressure with subsequent stomach inflation; this may occur frequently when rescuers without daily experience in bag-valve-mask ventilation need to perform advanced airway management. The purpose of this study was to assess the effects of a newly developed self-inflating bag (mouth-to-bag resuscitator; Ambu, Glostrup, Denmark) that limits peak inspiratory flow. A bench model simulating a patient with an unintubated airway was used, consisting of a face mask, manikin head, training lung (lung compliance, 100 ml/0.098 kPa (100 ml/cm H(2)O)); airway resistance, 0.39 kPa/l per second (4 cm H(2)O/l/s), oesophagus (LESP, 1.96 kPa (20 cm H(2)O)) and simulated stomach. Twenty nurses were randomised to ventilate the manikin for 1 min (respiratory rate: 12 per minute) with either a standard self-inflating bag or the mouth-to-bag resuscitator, which requires the rescuer to blow up a single-use balloon inside the self-inflating bag, which in turns displaces air towards the patient. When supplemental oxygen is added, ventilation with up to 100% oxygen may be obtained, since expired air is only used as the driving gas. The mouth-to-bag resuscitator therefore allows two instead of one hand sealing the mask on the patient's face. The volunteers were blinded to the experimental design of the model until completion of the experimental protocol. The mouth-to-bag resuscitator versus standard self-inflating bag resulted in significantly (P<0.05) higher mean+/-S.D. mask tidal volumes (1048+/-161 vs. 785+/-174 ml) and lung tidal volumes (911+/-148 vs. 678+/-157 ml), longer inspiratory times (1.7+/-0.4 vs. 1.4+/-0.4 s), but significantly lower peak inspiratory flow rates (50+/-9 vs. 62+/-13 l/min) and mask leakage (10+/-4 vs. 15+/-9%); peak inspiratory pressure (17+/-2 vs. 17+/-2 cm H(2)O) and stomach tidal volumes (16+/-30 vs. 18+/-35 ml) were comparable. In conclusion, employing the mouth-to-bag resuscitator during simulated ventilation of an unintubated patient in respiratory arrest significantly decreased inspiratory flow rate and improved lung tidal volumes, while decreasing mask leakage.

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Trending Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
12589994
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"