Clinical Trial
Comparative Study
Journal Article
Randomized Controlled Trial
Add like
Add dislike
Add to saved papers

Stability of the LMA-ProSeal and standard laryngeal mask airway in different head and neck positions: a randomized crossover study.

BACKGROUND AND OBJECTIVE: The LMA-ProSeal laryngeal mask airway is a new laryngeal mask airway with a modified cuff and drainage tube. We compared oropharyngeal leak pressure, intracuff pressure and anatomical position (assessed fibreoptically) for the Size 5 LMA-ProSeal laryngeal mask airway and the classic laryngeal mask airway in different head-neck positions and using different intracuff inflation volumes.

METHODS: Thirty paralysed anaesthetized adult male patients were studied. The LMA-ProSeal laryngeal mask airway and the classic laryngeal mask airway were inserted into each patient in random order. The oropharyngeal leak pressure, intracuff pressure, and anatomical position of the airway tube and drainage tube (LMA-ProSeal laryngeal mask airway only) were documented in four head and neck positions (neutral first, then flexion, extension and rotation in random order), and at 0-40 mL cuff volumes in the neutral position in 10 mL increments.

RESULTS: Compared with the neutral position, the oropharyngeal leak pressure for both the LMA-ProSeal laryngeal mask airway and the classic laryngeal mask airway was higher in flexion and rotation (all P < or = 0.02), but lower in extension (all P < or = 0.01). Changes in head-neck position did not alter the anatomical position of the airway tube or the drainage tube. The oropharyngeal leak pressure was always higher for the LMA-ProSeal laryngeal mask airway (all P < or = 0.005) and anatomical position better for the classic laryngeal mask airway (all P < or = 0.04).

CONCLUSIONS: The anatomical position of the LMA-ProSeal and the classic laryngeal mask airway is stable in different head-neck positions, but head-neck flexion and rotation are associated with an increase, and head-neck extension a decrease, in oropharyngeal leak pressure and intracuff pressure. The Size 5 LMA-ProSeal laryngeal mask airway is capable of forming a more effective seal than the Size 5 classic laryngeal mask airway in males.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app