Lancet 2003 January 19
BACKGROUND: Plague is often fatal without prompt and appropriate treatment. It affects mainly poor and remote populations. Late diagnosis is one of the major causes of human death and spread of the disease, since it limits the effectiveness of control measures. We aimed to develop and assess a rapid diagnostic test (RDT) for plague.

METHODS: We developed a test that used monoclonal antibodies to the F1 antigen of Yersinia pestis. Sensitivity and specificity were assessed with a range of bacterial cultures and clinical samples, and compared with findings from available ELISA and bacteriological tests for plague. Samples from patients thought to have plague were tested with the RDT in the laboratory and by health workers in 26 pilot sites in Madagascar.

FINDINGS: The RDT detected concentrations of F1 antigen as low as 0.5 ng/mL in up to 15 min, and had a shelf life of 21 days at 60 degrees C. Its sensitivity and specificity were both 100%. RDT detected 41.6% and 31% more positive clinical specimens than did bacteriological methods and ELISA, respectively. The agreement rate between tests done at remote centres and in the laboratory was 89.8%. With the combination of bacteriological methods and F1 ELISA as reference standard, the positive and negative predictive values of the RDT were 90.6% and 86.7%, respectively.

INTERPRETATION: Our RDT is a specific, sensitive, and reliable test that can easily be done by health workers at the patient's bedside, for the rapid diagnosis of pneumonic and bubonic plague. This test will be of key importance for the control of plague in endemic countries.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app