Phosphatidylserine exposure in platelet concentrates during the storage period: differences between the platelets collected with different cell separators.
Transfusion and Apheresis Science 2002 December
BACKGROUND AND OBJECTIVES: Platelet alterations occur during the production and storage of platelet concentrates, the so called "storage lesion". We studied the platelet alterations during the storage period in apheresis concentrates, employing flow cytometry for phosphatidylserine (PS) detection on platelets during the five days of storage.
MATERIAL AND METHODS: Twenty-seven single donor platelet concentrates harvested with the Cobe Trima, Baxter Amicus, or Haemonetics MCS+ were analyzed for PS exposure by flow cytometry on the day of production (day 1) and on days 3 and 5 of storage. Furthermore PS expression was analyzed in platelet donors' blood samples withdrawn before plateletpheresis.
RESULTS: PS expression on platelets gave the following median values: in blood donors before apheresis it was 1.12% (0.13-1.78) in platelets concentrates on the first day (2 h after apheresis) 2.06% (0.66-15.2), the third day 6.57% (1.98-51.13) and the fifth day 23.04% (3.86-80.23). All differences between median values of PS expression in blood samples before apheresis, and platelets concentrates on days 1, 3 and 5 of storage, are statistically significant. The expression of PS in platelet concentrates was analyzed in relation to the blood cell separator used for the collection procedure and showed the following results: on day 1 the median values of PS in platelet concentrates collected with the three different blood cell separators, Trima, Cobe and MCS, did not show statistically significant differences. On day 3, the platelets concentrates collected with the Trima and with the MCS showed differences that were statistically significant. Those were respectively 10.59% (4.56-51.13) and 3.53% (1.98-12.61), p = 0.005. The PS expression in platelet concentrates collected with the Trima and MCS showed differences that are also statistically significant on day 5 at respectively 32.4% (9.61-80.23) and 8.57% (3.86-48.42), p = 0.005.
CONCLUSIONS: PS exposure in platelet concentrates on days 3 and 5 rise to levels that could compromise the quality of the platelet units. Improvements in standardized platelet quality controls, and in platelet collection systems are required to reduce the storage lesions in platelets concentrates.
MATERIAL AND METHODS: Twenty-seven single donor platelet concentrates harvested with the Cobe Trima, Baxter Amicus, or Haemonetics MCS+ were analyzed for PS exposure by flow cytometry on the day of production (day 1) and on days 3 and 5 of storage. Furthermore PS expression was analyzed in platelet donors' blood samples withdrawn before plateletpheresis.
RESULTS: PS expression on platelets gave the following median values: in blood donors before apheresis it was 1.12% (0.13-1.78) in platelets concentrates on the first day (2 h after apheresis) 2.06% (0.66-15.2), the third day 6.57% (1.98-51.13) and the fifth day 23.04% (3.86-80.23). All differences between median values of PS expression in blood samples before apheresis, and platelets concentrates on days 1, 3 and 5 of storage, are statistically significant. The expression of PS in platelet concentrates was analyzed in relation to the blood cell separator used for the collection procedure and showed the following results: on day 1 the median values of PS in platelet concentrates collected with the three different blood cell separators, Trima, Cobe and MCS, did not show statistically significant differences. On day 3, the platelets concentrates collected with the Trima and with the MCS showed differences that were statistically significant. Those were respectively 10.59% (4.56-51.13) and 3.53% (1.98-12.61), p = 0.005. The PS expression in platelet concentrates collected with the Trima and MCS showed differences that are also statistically significant on day 5 at respectively 32.4% (9.61-80.23) and 8.57% (3.86-48.42), p = 0.005.
CONCLUSIONS: PS exposure in platelet concentrates on days 3 and 5 rise to levels that could compromise the quality of the platelet units. Improvements in standardized platelet quality controls, and in platelet collection systems are required to reduce the storage lesions in platelets concentrates.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app