We have located links that may give you full text access.
EVALUATION STUDIES
RESEARCH SUPPORT, NON-U.S. GOV'T
Evaluation and optimization of capillary zone electrophoresis with different dynamic capillary coatings for the determination of carbohydrate-deficient transferrin in human serum.
Journal of Chromatography. A 2002 December 7
Serum transferrin (Tf) comprises several isoforms with up to two complex oligosaccharide chains containing zero to eight sialic acid residues and neutral sugars. The major glycoform, known as tetrasialo-Tf, contains four sialic acid residues and accounts for about 80% of whole Tf in human serum. Carbohydrate-deficient transferrin (CDT) encompasses isoforms that are deficient in carbohydrate chains and consequently in sialic acid residues (including asialo-, monosialo- and disialo-Tf) and is a well known marker for chronic alcohol abuse. Recently capillary zone electrophoresis (CZE) has been reported as a tool extremely effective for the simultaneous, individual, quantitative determination of CDT isoforms. Three CZE methods that feature different dynamic capillary coatings were evaluated and optimized for CDT determination in human serum of alcohol abusers and control subjects. CZE separation was performed in alkaline borate buffers after serum sample saturation with iron, electropherograms were detected at 200 nm, data were evaluated as % area of disialo-Tf in relation to tetrasialo-Tf and peak identification was accomplished via relative migration times to tetrasialo-Tf, immunosubtraction and enzymatic sequential cleavage of sialic acid residues. Dynamic capillary coatings with diaminobutane, spermine and a double coating produced by commercially available proprietary agents were investigated and found to be suitable for determination of CDT in human serum. For all three approaches, best results were obtained in 50 microm I.D. fused-silica capillaries of 50 cm effective length and a capillary cartridge temperature of 20-25 degrees C. Using 3 mM 1,4-diaminobutane or 0.02 mM spermine in a borate-based running buffer of pH 8.3 provided data of remarkable similarity with resolution of di-, tri-, tetra- and pentasialo-Tf within 15-18 min. With the double coating, asialo-Tf and Tf isoforms with two to six sialic acid residues were baseline separated. Compared to the two amine-based procedures, the run times were found to be somewhat shorter, the detector signals higher, the applied power level significantly lower and the reproducibility better.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app