BACKGROUND: The cuffed oropharyngeal airway (COPA) is a modified Guedel-type oral airway with a cuff at its distal end. The objectives of this prospective, randomized study were to compare the COPA and the laryngeal mask airway (LMA) in terms of propofol requirement with and without fentanyl pretreatment for smooth insertions.

METHODS: Seventy-five patients undergoing general anaesthesia were randomly assigned to either a COPA (n=38) or LMA (n=37) group for airway management, and each group was further randomized to a saline-propofol or fentanyl-propofol group for anaesthesia induction. The saline-propofol group received i.v. saline and the fentanyl-propofol group received i.v. fentanyl 1 micro g kg(-1) followed 30 s later by i.v. propofol. Insertion of the device was attempted 90 s after propofol administration without the use of neuromuscular blocking agents or other adjuvants, and the responses of 'movement' or 'no movement' were judged by three observers blinded to the drug dose. Each dose of propofol at which insertion was attempted was predetermined by modification of Dixon's up-and-down method with 0.5 mg kg(-1) as the step size, and 2 mg kg(-1) as an initial dose.

RESULTS: Without fentanyl pretreatment, propofol requirement [mean (SD), 95% CI] for COPA placement [2.17 (0.38), 1.77-2.56 mg kg(-1)] was significantly less than for LMA insertion [3.42 (0.26), 3.15-3.69 mg kg(-1), P<0.001]. In contrast, propofol requirements after fentanyl were comparable between the COPA and LMA groups [1.50 (0.42), 1.06-1.94 and 1.42 (0.26), 1.15-1.69 mg kg(-1), respectively], but were less than for the placebo group with both devices (P<0.05). Haemodynamic changes and duration of apnoea were similar with both devices irrespective of fentanyl pretreatment.

CONCLUSIONS: Insertion of the COPA can be accomplished with a smaller bolus dose of propofol compared with the LMA, but propofol requirements are similar with both devices after a small dose of fentanyl.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app