A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process.

OBJECTIVE: The condylar region is one of the most frequent sites for mandibular fractures, with direct application of miniplates being the most commonly used open-fixation technique today. Yet, anatomic and biomechanical limitations continue to make this application technically challenging with a considerable complication rate. We sought to analyze such incongruencies with respect to the complex biomechanical behavior of the mandible.

STUDY DESIGN: Individual human mandible geometry, the specific bone density distribution, and the position and orientation of the masticatory muscles were evaluated by performing computed tomography scans and a sequential dissection of the cadaver mandible. Three-dimensional finite-element analysis was performed for different fracture sites, osteosynthesis plates, and loading conditions.

RESULTS: Osteosynthesis of fractures of the condylar neck with 1 or 2 miniplates of a diameter of 2.35 x 1.00 mm was found to be an insufficient fixation method. This also applies for plates (3.60 x 1.54 mm), according to Pape et al,(8) when used in singular fashion (high condylar neck fractures excepted). In cases of singular occlusal contacts in the molar region (particularly at the contralateral side of the fracture), the highest stress values inside the mandible and osteosynthetic devices could be observed. With even the static yield limit of titanium being exceeded in such cases, consecutive rapid failure of the miniplates becomes most likely when loading of the condylar region caused by bite forces cannot be prevented.

CONCLUSION: We strongly recommend the use, whenever possible, of 2 plates in the manner described by Pape et al(8) for osteosynthesis of fractures of the condylar neck in combination with bicortically placed screws. The stiffness of a singular osteosynthesis plate made of titanium in a diametrical dimension of approximately 5.0 x 1.75 mm was found to be equivalent to the physiological bone stiffness in the investigated fracture sites. The actual stiffness of such a fixation plate is approximately 3 times higher than the stiffness of devices commonly in use.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app