JOURNAL ARTICLE
A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process.
OBJECTIVE: The condylar region is one of the most frequent sites for mandibular fractures, with direct application of miniplates being the most commonly used open-fixation technique today. Yet, anatomic and biomechanical limitations continue to make this application technically challenging with a considerable complication rate. We sought to analyze such incongruencies with respect to the complex biomechanical behavior of the mandible.
STUDY DESIGN: Individual human mandible geometry, the specific bone density distribution, and the position and orientation of the masticatory muscles were evaluated by performing computed tomography scans and a sequential dissection of the cadaver mandible. Three-dimensional finite-element analysis was performed for different fracture sites, osteosynthesis plates, and loading conditions.
RESULTS: Osteosynthesis of fractures of the condylar neck with 1 or 2 miniplates of a diameter of 2.35 x 1.00 mm was found to be an insufficient fixation method. This also applies for plates (3.60 x 1.54 mm), according to Pape et al,(8) when used in singular fashion (high condylar neck fractures excepted). In cases of singular occlusal contacts in the molar region (particularly at the contralateral side of the fracture), the highest stress values inside the mandible and osteosynthetic devices could be observed. With even the static yield limit of titanium being exceeded in such cases, consecutive rapid failure of the miniplates becomes most likely when loading of the condylar region caused by bite forces cannot be prevented.
CONCLUSION: We strongly recommend the use, whenever possible, of 2 plates in the manner described by Pape et al(8) for osteosynthesis of fractures of the condylar neck in combination with bicortically placed screws. The stiffness of a singular osteosynthesis plate made of titanium in a diametrical dimension of approximately 5.0 x 1.75 mm was found to be equivalent to the physiological bone stiffness in the investigated fracture sites. The actual stiffness of such a fixation plate is approximately 3 times higher than the stiffness of devices commonly in use.
STUDY DESIGN: Individual human mandible geometry, the specific bone density distribution, and the position and orientation of the masticatory muscles were evaluated by performing computed tomography scans and a sequential dissection of the cadaver mandible. Three-dimensional finite-element analysis was performed for different fracture sites, osteosynthesis plates, and loading conditions.
RESULTS: Osteosynthesis of fractures of the condylar neck with 1 or 2 miniplates of a diameter of 2.35 x 1.00 mm was found to be an insufficient fixation method. This also applies for plates (3.60 x 1.54 mm), according to Pape et al,(8) when used in singular fashion (high condylar neck fractures excepted). In cases of singular occlusal contacts in the molar region (particularly at the contralateral side of the fracture), the highest stress values inside the mandible and osteosynthetic devices could be observed. With even the static yield limit of titanium being exceeded in such cases, consecutive rapid failure of the miniplates becomes most likely when loading of the condylar region caused by bite forces cannot be prevented.
CONCLUSION: We strongly recommend the use, whenever possible, of 2 plates in the manner described by Pape et al(8) for osteosynthesis of fractures of the condylar neck in combination with bicortically placed screws. The stiffness of a singular osteosynthesis plate made of titanium in a diametrical dimension of approximately 5.0 x 1.75 mm was found to be equivalent to the physiological bone stiffness in the investigated fracture sites. The actual stiffness of such a fixation plate is approximately 3 times higher than the stiffness of devices commonly in use.
Full text links
Trending Papers
Role of Iron Deficiency in Heart Failure-Clinical and Treatment Approach: An Overview.Diagnostics 2023 January 14
Systemic complications of rheumatoid arthritis: Focus on pathogenesis and treatment.Frontiers in Immunology 2022
Long COVID: major findings, mechanisms and recommendations.Nature Reviews. Microbiology 2023 January 14
2023 American Society of Anesthesiologists Practice Guidelines for Preoperative Fasting: Carbohydrate-containing Clear Liquids with or without Protein, Chewing Gum, and Pediatric Fasting Duration-A Modular Update of the 2017 American Society of Anesthesiologists Practice Guidelines for Preoperative Fasting.Anesthesiology 2023 Februrary 2
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app