Correction of ionized plasma magnesium during cardiopulmonary bypass reduces the risk of postoperative cardiac arrhythmia.
Anesthesia and Analgesia 2002 October
UNLABELLED: We conducted this randomized controlled trial to determine whether the intraoperative measurement and correction of ionized plasma magnesium can reduce the risk of cardiac arrhythmia after cardiopulmonary bypass. Eighty-five patients presenting for coronary artery bypass grafting were randomly assigned either to the magnesium-corrected group, which received magnesium sulfate on the basis of measured levels of ionized plasma magnesium (n = 43), or to the control group, in which magnesium levels were identified but not corrected (n = 42). Ionized magnesium was determined with an ion-selective electrode with minimal delay, and further samples were taken for laboratory analysis of total plasma magnesium. All patients had Holter electrocardiogram monitoring for 72 h after surgery. Total hypomagnesemia (45 patients; 53% of all patients) was more common than ionized hypomagnesemia (11 patients; 13%) before cardiopulmonary bypass. Both total and ionized magnesium levels declined further during the course of cardiopulmonary bypass in the control group. The incidence of ventricular tachycardia in the first 24 h was less frequent in the magnesium-corrected group (3 patients; 7%) than the control group (12 patients, 30%; P < 0.01). Patients in the magnesium-corrected group were more likely to display continuous sinus rhythm (Lown Grade 0) in the first 24 h (14 patients; 34%) than patients in the control group (2 patients, 5%; P < 0.001). Our results suggest that the intraoperative correction of ionized magnesium is associated with a reduction in postoperative ventricular arrhythmia in cardiac surgical patients.
IMPLICATIONS: In this study the correction of ionized plasma magnesium during cardiopulmonary bypass was guided by measurements from an ion-selective electrode. This intervention resulted in a reduction in the incidence of postoperative ventricular tachycardia and an increased frequency of continuous sinus rhythm. Ion-selective electrodes constitute a convenient near-patient test, providing a basis for the targeted replacement of ionized plasma magnesium.
IMPLICATIONS: In this study the correction of ionized plasma magnesium during cardiopulmonary bypass was guided by measurements from an ion-selective electrode. This intervention resulted in a reduction in the incidence of postoperative ventricular tachycardia and an increased frequency of continuous sinus rhythm. Ion-selective electrodes constitute a convenient near-patient test, providing a basis for the targeted replacement of ionized plasma magnesium.
Full text links
Trending Papers
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines.Circulation 2023 November 31
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app