We have located links that may give you full text access.
CLINICAL TRIAL
JOURNAL ARTICLE
Low-output, low-gradient aortic stenosis in patients with depressed left ventricular systolic function: the clinical utility of the dobutamine challenge in the catheterization laboratory.
Circulation 2002 August 14
BACKGROUND: Although aortic valve replacement can be performed at an acceptable risk level in selected patients with left ventricular systolic dysfunction and low-output, low-gradient aortic stenosis, not all patients presenting with these hemodynamics will benefit from the operation. Some patients may have only mild aortic stenosis, despite a small calculated valve area. We report on the clinical utility of diagnostic dobutamine stimulation during cardiac catheterization in these diagnostically challenging patients.
METHODS AND RESULTS: Thirty-two patients with low-output, low-gradient aortic stenosis and an ejection fraction <40% had dobutamine infusion in the catheterization laboratory. On the basis of the results of the dobutamine test, 21 patients underwent aortic valve replacement. All patients with a final aortic valve area < or =1.2 cm2 at peak dobutamine infusion and a mean gradient of >30 mm Hg were found to have severe calcific aortic stenosis at operation. In the 15 patients in whom contractile reserve was identified during dobutamine challenge (increase in stroke volume >20%), 1 patient died perioperatively (7% mortality) and 12 patients were alive in New York Heart Association class I or II status at follow-up.
CONCLUSIONS: In patients with left ventricular systolic dysfunction and aortic stenosis with a low output and a low mean gradient, dobutamine challenge may aid in selecting those who would benefit from an aortic valve operation.
METHODS AND RESULTS: Thirty-two patients with low-output, low-gradient aortic stenosis and an ejection fraction <40% had dobutamine infusion in the catheterization laboratory. On the basis of the results of the dobutamine test, 21 patients underwent aortic valve replacement. All patients with a final aortic valve area < or =1.2 cm2 at peak dobutamine infusion and a mean gradient of >30 mm Hg were found to have severe calcific aortic stenosis at operation. In the 15 patients in whom contractile reserve was identified during dobutamine challenge (increase in stroke volume >20%), 1 patient died perioperatively (7% mortality) and 12 patients were alive in New York Heart Association class I or II status at follow-up.
CONCLUSIONS: In patients with left ventricular systolic dysfunction and aortic stenosis with a low output and a low mean gradient, dobutamine challenge may aid in selecting those who would benefit from an aortic valve operation.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app