We have located links that may give you full text access.
Undersurface ablation of the flap for laser in situ keratomileusis retreatment.
Ophthalmology 2002 August
OBJECTIVE: To develop a novel technique, undersurface ablation of the flap (UAF), for laser in situ keratomileusis (LASIK) retreatment in eyes with insufficient posterior stroma.
DESIGN: Noncomparative, interventional case series.
PARTICIPANTS: From 30 eyes examined, 25 eyes with a spherical equivalent residual refraction between -0.75 and -3.25 diopters (D) and astigmatism between 0.0 and -1.5 D were prospectively included in the study. In these eyes, calculated postenhancement flap thickness was >150 micro m using micropachymetric optical coherence tomography (OCT), whereas with further ablation of the bed, posterior stromal thickness would have been <250 micro m. Primary LASIK procedures had been performed with the Hansatome microkeratome.
INTERVENTION: The flap was lifted and the eye deviated downward, so that the corneal visual axis mark aligned with the laser beam. Mirror pattern ablations with an optical zone of 5 mm were performed on the flap stroma using either the Summit Apex Plus excimer laser or the Technolas Keracor 217 spot-scanning excimer laser. New axis orientation for toric ablations was calculated with the formula: beta = 180 degrees - alpha.
MAIN OUTCOME MEASURES: Refraction, visual acuity, OCT pachymetry, tangential videokeratography, and patient satisfaction.
RESULTS: The average follow-up was 6.36 +/- 2.64 months (range, 3-12 months). Mean preenhancement spherical equivalent (-2.05 +/- 0.75 D) was reduced to -0.19 +/- 0.38 D at the last visit (P = 0.001). Mean cylinder decreased from -0.48 +/- 0.53 D before retreatment to -0.23 +/- 0.28 D at the last follow-up (P = 0.003). Best-corrected visual acuity worsened by 1 line in two eyes (8%), and no eye lost 2 or more lines. Satisfactory globe stabilization and stromal smoothness during ablation were more difficult to achieve than with conventional LASIK enhancements. The average central flap thickness before UAF, 187 +/- 13 micro m, decreased to 164 +/- 12 micro m after 1 month (P = 0.001). No keratectasia developed. Finally, 92% of cases were satisfied with surgery compared with 48% before UAF retreatment (P = 0.001).
CONCLUSIONS: UAF retreatment for low residual refractive errors after LASIK in eyes with sufficient flap stroma seems to be effective and may prevent future keratectasia.
DESIGN: Noncomparative, interventional case series.
PARTICIPANTS: From 30 eyes examined, 25 eyes with a spherical equivalent residual refraction between -0.75 and -3.25 diopters (D) and astigmatism between 0.0 and -1.5 D were prospectively included in the study. In these eyes, calculated postenhancement flap thickness was >150 micro m using micropachymetric optical coherence tomography (OCT), whereas with further ablation of the bed, posterior stromal thickness would have been <250 micro m. Primary LASIK procedures had been performed with the Hansatome microkeratome.
INTERVENTION: The flap was lifted and the eye deviated downward, so that the corneal visual axis mark aligned with the laser beam. Mirror pattern ablations with an optical zone of 5 mm were performed on the flap stroma using either the Summit Apex Plus excimer laser or the Technolas Keracor 217 spot-scanning excimer laser. New axis orientation for toric ablations was calculated with the formula: beta = 180 degrees - alpha.
MAIN OUTCOME MEASURES: Refraction, visual acuity, OCT pachymetry, tangential videokeratography, and patient satisfaction.
RESULTS: The average follow-up was 6.36 +/- 2.64 months (range, 3-12 months). Mean preenhancement spherical equivalent (-2.05 +/- 0.75 D) was reduced to -0.19 +/- 0.38 D at the last visit (P = 0.001). Mean cylinder decreased from -0.48 +/- 0.53 D before retreatment to -0.23 +/- 0.28 D at the last follow-up (P = 0.003). Best-corrected visual acuity worsened by 1 line in two eyes (8%), and no eye lost 2 or more lines. Satisfactory globe stabilization and stromal smoothness during ablation were more difficult to achieve than with conventional LASIK enhancements. The average central flap thickness before UAF, 187 +/- 13 micro m, decreased to 164 +/- 12 micro m after 1 month (P = 0.001). No keratectasia developed. Finally, 92% of cases were satisfied with surgery compared with 48% before UAF retreatment (P = 0.001).
CONCLUSIONS: UAF retreatment for low residual refractive errors after LASIK in eyes with sufficient flap stroma seems to be effective and may prevent future keratectasia.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app