Comparative Study
Evaluation Studies
Journal Article
Add like
Add dislike
Add to saved papers

Blood glucose self-monitoring from abdominal skin: a precise and virtually pain-free method.

For many diabetic patients, years of blood glucose self-monitoring (SM) with readings taken several times daily is an inevitable aspect of insulin therapy. We investigated whether SM from abdominal skin might be an alternative to the established fingertip method. A total of 63 diabetic patients and 16 nondiabetic volunteers determined their blood glucose in parallel in capillary blood from the tip of the finger and from abdominal skin 5 times daily on 5 successive days. The blood samples were collected from the two test regions using lancing devices, and the SM determinations were all done with a meter. Consecutive specific enzymatic glucose determinations in blood from the fingertip served as the reference method. The results of the SM from abdominal skin, a method perceived as virtually painless, were in close correlation with the control laboratory determinations and with SM from the finger (Pearson's r, 0.94 and 0.95). The comparison of SM method for abdomen vs. finger laboratory control gave a linear regression equation of y=8.35+0.94x (r=0.94). Error grid analysis revealed: range A, 93.6%; range B, 5.4%; range C, 0.05%; range D, 1.0%; and range E, 0%. Bland and Altman analysis yielded the mean of the differences, 0.2 mg/dl; 2 SD, 32 mg/dl; minimum, -162 mg/dl; maximum, 148 mg/dl. Laboratory glucose determinations in capillary blood from the fingertip and from abdominal skin led in 99.7% of the cases to concordant therapeutic decisions in the diabetics; the sample material was therefore equivalent. The practical aspects (afterbleeding, number of punctures, test strip consumption) of SM from the two regions showed no essential differences. However, only 22% of the diabetic patients investigated continued to perform SM from abdominal skin on a longer basis. In a further 5 adipose diabetic patients (BMI, 32 kg/M2), SM from abdominal skin was not practicable, as there was insufficient blood to collect. SM from abdomal skin is a simple, virtually pain-free and precise method. It provides certain diabetic patients with an alternative to the established method of SM from the fingertip.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app