The effect of augmentation with resorbable or conventional bone cement on the holding strength for femoral neck fracture devices.
Journal of Orthopaedic Trauma 2002 May
OBJECTIVES: To compare maximum extraction torque and pull-out load for femoral neck fracture implants inserted with standard technique or after augmentation with polymethylmethacrylate (PMMA) or calcium phosphate cement (Norian SRS).
DESIGN: Biomechanical study using synthetic bone.
INTERVENTION: Implants were inserted in foam blocks with three different densities for simulation of normal bone or slight or severe osteoporosis. Tested implants included three screws (AO, Olmed, Hansson), one screw with both threads and a barb (Hybrid), and one pin with a hook (LIH hook-pin). Implants were inserted by standard technique and after augmentation with PMMA or Norian SRS.
MAIN OUTCOME MEASUREMENT: The effect of (a) density of the synthetic bone (low, medium, high), (b) augmentation (none, PMMA, SRS), and (c) type of implant (AO, Olmed, Hansson, Hybrid, LIH) on the maximum extraction torque and pull-out load was determined using a material testing machine. Analysis of variance with Fisher's PLSD post hoc test was used to determine statistical differences.
RESULTS: PMMA significantly increased maximum torque and pull-out load for all implants and block densities when compared without cement (p < 0.0001), whereas enhancement with SRS was far less pronounced and most obvious in low density blocks. For screws normally inserted without predrilling (Olmed and Hansson) the use of SRS in high density blocks caused a significant reduction in maximum torque (p < 0.0001) and pull-out load (p < 0.0001). SRS-augmented specimens failed through the cement at the periphery of the threads, whereas PMMA-augmented specimens failed between the cement and the synthetic bone.
CONCLUSION: This study suggests that augmentation with PMMA around femoral neck fracture implants will increase the holding power significantly when compared with standard insertion technique as well as augmentation with calcium phosphate cement. Augmentation with calcium phosphate cement like SRS will increase the holding characteristics mainly in low density bone, whereas in high density bone it might even reduce the maximum torque because of the need for predrilling when using the cement for augmentation.
DESIGN: Biomechanical study using synthetic bone.
INTERVENTION: Implants were inserted in foam blocks with three different densities for simulation of normal bone or slight or severe osteoporosis. Tested implants included three screws (AO, Olmed, Hansson), one screw with both threads and a barb (Hybrid), and one pin with a hook (LIH hook-pin). Implants were inserted by standard technique and after augmentation with PMMA or Norian SRS.
MAIN OUTCOME MEASUREMENT: The effect of (a) density of the synthetic bone (low, medium, high), (b) augmentation (none, PMMA, SRS), and (c) type of implant (AO, Olmed, Hansson, Hybrid, LIH) on the maximum extraction torque and pull-out load was determined using a material testing machine. Analysis of variance with Fisher's PLSD post hoc test was used to determine statistical differences.
RESULTS: PMMA significantly increased maximum torque and pull-out load for all implants and block densities when compared without cement (p < 0.0001), whereas enhancement with SRS was far less pronounced and most obvious in low density blocks. For screws normally inserted without predrilling (Olmed and Hansson) the use of SRS in high density blocks caused a significant reduction in maximum torque (p < 0.0001) and pull-out load (p < 0.0001). SRS-augmented specimens failed through the cement at the periphery of the threads, whereas PMMA-augmented specimens failed between the cement and the synthetic bone.
CONCLUSION: This study suggests that augmentation with PMMA around femoral neck fracture implants will increase the holding power significantly when compared with standard insertion technique as well as augmentation with calcium phosphate cement. Augmentation with calcium phosphate cement like SRS will increase the holding characteristics mainly in low density bone, whereas in high density bone it might even reduce the maximum torque because of the need for predrilling when using the cement for augmentation.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app