The effect of axial tibial torque on the function of the anterior cruciate ligament: a biomechanical study of a simulated pivot shift test.

Arthroscopy 2002 April
PURPOSE: Various techniques are used to produce the pivot shift phenomenon after anterior cruciate ligament (ACL) injury. In particular, the amount of applied axial tibial torque varies among examiners. Thus, the objective of this study was to determine the effect of the magnitude and direction of axial tibial torque in combination with valgus torque on the resulting knee kinematics during such a simulated pivot shift test.

TYPE OF STUDY: This was a biomechanical study that used cadaveric knees with the intact knee of the same specimen serving as a control.

METHODS: On 19 human cadaveric knees (age, 26 to 69 years), a constant 10-Nm valgus torque was applied at 15 degrees of knee flexion. Then, internal and external tibial torque was applied incrementally from 0 to 10 Nm and the resulting kinematics of the ACL-intact and ACL-deficient knee, as well as the in situ force in the ACL, were measured using a robotic/universal force-moment sensor testing system.

RESULTS: In response to isolated valgus torque, the coupled anterior tibial translation for the ACL-intact and ACL-deficient knee was 1.6 +/- 2.4 mm and 8.5 +/- 4.7 mm, respectively; therefore the difference between the ACL-intact and ACL-deficient knee was 6.9 +/- 3.4 mm. With an external tibial torque greater than 5 Nm, the tibia translated up to 4 mm posteriorly for both the ACL-intact and ACL-deficient knee. Whereas, internal tibial torque greater than 1.6 Nm caused a rapid increase in coupled anterior tibial translation up to 10.2 mm in the ACL-deficient knee, while causing only a gradual increase for the ACL-intact knee. With excessive internal torque of 10 Nm, the difference in coupled anterior tibial translation was only 4.4 +/- 2.2 mm, suggesting a decrease in the sensitivity of the test. Correspondingly, the in situ force in the ACL under 10 Nm valgus tibial torque was 43 +/- 17 N, and increased up to 87 +/- 32 N as a 10-Nm internal torque was added. By applying a 3.3-Nm external tibial torque in addition to the 10-Nm valgus torque, the in situ force decreased to 21 +/- 14 N.

CONCLUSIONS: This study showed that a minimal amount of internal torque in combination with valgus torque may be a suitable way to elicit a pivot shift from an ACL-deficient knee.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app