COMPARATIVE STUDY
JOURNAL ARTICLE

A comparative multi-laboratory assessment of three factor VIII/von Willebrand factor concentrates

Emmanuel J Favaloro, Melinda Bukuya, Teresa Martinelli, Joanne Tzouroutis, Elizabeth Duncan, Katie Welldon, Margaret Collecutt, Heather Aumann, Jim Thom, Grace Gilmore
Thrombosis and Haemostasis 2002, 87 (3): 466-76
11916080
Five expert laboratories have participated in a cross-laboratory study to co-evaluate and compare three commercial Factor VIII/von Willebrand factor (VWF) concentrates. A total of nine factor concentrate lots were evaluated, comprising AHF (High Purity) (AHF HP; x3), Biostate (x3) and Humate/Haemate (x3). All laboratories blind tested for FVIII: C, VWF: Ag and VWF: CB, four tested for VWF: RCo, and one performed VWF: Multimers. The study yielded inter-laboratory CVs for VWF: Ag and FVIII:C around 10-15%, and for VWF:CB and VWF:RCo around 20%, significantly lower than those of previous multi-laboratory surveys. All three lots of AHF HP contained in the vicinity of 25 U/ml FVIII:C, around 60-75 U/ml of VWF:Ag, but only 30-45 U/ml of VWF:CB and 40-50 U/ml of VWF:RCo (thus, CB/Ag ratio around 0.5-0.6 and RCo/Ag ratio around 0.6-0.7). Study determined that FVIII: C and VWF: RCo levels were similar to manufacturer assigned levels. Some loss of the high molecular weight (HMW) multimers was observed, together with an intense low molecular weight (LMW) VWF band consistent with some reduction or proteolysis of HMW VWF. All three lots of Humate/Haemate contained in the vicinity of 23-32 U/ml of FVIII:C, 70-105 U/ml of VWF: Ag, 50-90 U/ml of VWF: CB and VWF: RCo (i.e. CB/Ag ratio around 0.6-0.9 and RCo/Ag ratio around 0.6-1.1). Study-determined FVIII: C and VWF: RCo levels were similar to manufacturer-assigned levels. The LMW multimer band seen with AHF HP was also observed with Humate/Haemate. All three lots of Biostate contained in the vicinity of 40-55 U/ml of FVIII:C, 105-170 U/ml of VWF:Ag, 90-150 U/ml of VWF:CB, and 90-135 U/ml of VWF:RCo (i.e. CB/Ag and RCo/Ag ratios around 0.7-1.0). Study-determined FVIII:C levels were similar to manufacturer-assigned levels. The LMW multimer band seen with AHF HP was not observed with Biostate. The defined pattern of increasing CB/ Ag from AHF HP to Humate/Haemate and Biostate was consistently observed in study data from each of the five laboratories. In conclusion, study findings indicate some differences in the retention of functional/ HMW VWF between factor concentrates, and this is expected to have significant implications in terms of clinical efficacy for therapy in VWD.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Trending Papers

Remove bar
Read by QxMD icon Read
11916080
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"