Capnographic monitoring of anesthetized African grey parrots receiving intermittent positive pressure ventilation.
Journal of the American Veterinary Medical Association 2001 December 16
OBJECTIVE: To determine whether end-tidal partial pressure of carbon dioxide (PETCO2) correlated with PaCO2 in isoflurane-anesthetized African grey parrots receiving intermittent positive pressure ventilation (IPPV).
DESIGN: Prospective study.
ANIMALS: 14 healthy mature African grey parrots (Psittacus erithacus timnus).
PROCEDURE: Each bird was anesthetized via mask with isoflurane, intubated, and connected to a pressure-limited intermittent-flow ventilator. Respiratory rate was altered while holding peak inspiratory pressure constant (5 cm H2O) to achieve a PETCO2 in 1 of 3 ranges: < 30 mm Hg, 30 to 40 mm Hg, and > 40 mm Hg. Blood was collected from the superficial ulnar artery of each bird at least once during each of the 3 ranges. Arterial blood samples were collected for blood gas analysis while PETCO2 was recorded simultaneously.
RESULTS: A strong correlation between PETCO2 and PaCO2 was detected over a wide range of partial pressures, although PETCO2 consistently overestimated PaCO2 by approximately 5 mm Hg. End-tidal partial pressure of CO2 and PaCO2 also correlated well with arterial blood pH, and the acute response of the bicarbonate buffer system to changes in ventilation was similar to that of mammals.
CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that PETCO2 reliably estimates PaCO2 in isoflurane-anesthetized African grey parrots receiving IPPV and suggest that IPPV combined with capnography is a viable option for anesthetic maintenance in avian anesthesia.
DESIGN: Prospective study.
ANIMALS: 14 healthy mature African grey parrots (Psittacus erithacus timnus).
PROCEDURE: Each bird was anesthetized via mask with isoflurane, intubated, and connected to a pressure-limited intermittent-flow ventilator. Respiratory rate was altered while holding peak inspiratory pressure constant (5 cm H2O) to achieve a PETCO2 in 1 of 3 ranges: < 30 mm Hg, 30 to 40 mm Hg, and > 40 mm Hg. Blood was collected from the superficial ulnar artery of each bird at least once during each of the 3 ranges. Arterial blood samples were collected for blood gas analysis while PETCO2 was recorded simultaneously.
RESULTS: A strong correlation between PETCO2 and PaCO2 was detected over a wide range of partial pressures, although PETCO2 consistently overestimated PaCO2 by approximately 5 mm Hg. End-tidal partial pressure of CO2 and PaCO2 also correlated well with arterial blood pH, and the acute response of the bicarbonate buffer system to changes in ventilation was similar to that of mammals.
CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that PETCO2 reliably estimates PaCO2 in isoflurane-anesthetized African grey parrots receiving IPPV and suggest that IPPV combined with capnography is a viable option for anesthetic maintenance in avian anesthesia.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app