Optimal pinhole techniques for preoperative localization with Tc-99m MIBI for primary hyperparathyroidism.
Clinical Nuclear Medicine 2001 December
PURPOSE: Technetium-99m-labeled 2-methoxyisobutylisonitrile (Tc-99m MIBI) has been used extensively to localize parathyroid adenomas before operation. Imaging techniques vary widely, and the aim of this study was to determine the optimal time of delayed imaging and the value of routine correlative pertechnetate thyroid imaging.
MATERIALS AND METHODS: In this study, preoperative parathyroid localization was performed using pinhole anterior and oblique images (15 minutes and 2 and 4 hours after injection) with correlative pertechnetate thyroid images. Ninety-seven patients underwent dual- or triple-phase Tc-99m MIBI imaging and correlative pertechnetate thyroid imaging before surgery. Two nuclear medicine physicians blinded to the surgical findings interpreted all available images and various Tc-99m MIBI image combinations at 15 minutes alone; 15 minutes and 2 hours, 15 minutes and 4 hours; and 15 minutes and 2 and 4 hours each with and without correlative pertechnetate thyroid imaging.
RESULTS: Ninety parathyroid adenomas were detected in 86 patients. The optimal results were achieved with 15-minute and 2- and 4-hour Tc-99m-MIBI images, with correlative thyroid scans resulting in a sensitivity rate of 88%. Fifteen-minute and 2-hour Tc-99m-MIBI images and correlative thyroid scans and 15-minute and 4-hour Tc-99m MIBI images and correlative thyroid scans produced similar results (sensitivity rate, 86% and 83%, respectively; P = not significant). Compared with all Tc-99m MIBI image combinations alone, the addition of the routine correlative thyroid scan significantly improved sensitivity and also improved reporter confidence in 45% of studies.
CONCLUSIONS: Of the pinhole techniques compared, 15-minute and 2-hour Tc-99m MIBI images with correlative thyroid scanning may be the preferred imaging protocol, because this yields results similar to imaging for as long as 4 hours after injection in a shorter, more logistically acceptable imaging time.
MATERIALS AND METHODS: In this study, preoperative parathyroid localization was performed using pinhole anterior and oblique images (15 minutes and 2 and 4 hours after injection) with correlative pertechnetate thyroid images. Ninety-seven patients underwent dual- or triple-phase Tc-99m MIBI imaging and correlative pertechnetate thyroid imaging before surgery. Two nuclear medicine physicians blinded to the surgical findings interpreted all available images and various Tc-99m MIBI image combinations at 15 minutes alone; 15 minutes and 2 hours, 15 minutes and 4 hours; and 15 minutes and 2 and 4 hours each with and without correlative pertechnetate thyroid imaging.
RESULTS: Ninety parathyroid adenomas were detected in 86 patients. The optimal results were achieved with 15-minute and 2- and 4-hour Tc-99m-MIBI images, with correlative thyroid scans resulting in a sensitivity rate of 88%. Fifteen-minute and 2-hour Tc-99m-MIBI images and correlative thyroid scans and 15-minute and 4-hour Tc-99m MIBI images and correlative thyroid scans produced similar results (sensitivity rate, 86% and 83%, respectively; P = not significant). Compared with all Tc-99m MIBI image combinations alone, the addition of the routine correlative thyroid scan significantly improved sensitivity and also improved reporter confidence in 45% of studies.
CONCLUSIONS: Of the pinhole techniques compared, 15-minute and 2-hour Tc-99m MIBI images with correlative thyroid scanning may be the preferred imaging protocol, because this yields results similar to imaging for as long as 4 hours after injection in a shorter, more logistically acceptable imaging time.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app