Estimating menstrual blood loss in women with normal and excessive menstrual fluid volume.
Obstetrics and Gynecology 2001 November
OBJECTIVE: To examine the relationship between total fluid volume at menstruation and the volume of blood loss, and to assess the feasibility of using total fluid volume to estimate menstrual blood loss.
METHODS: Fifty-three women were studied over two menstrual periods each. Hemoglobin in menstrual pads and tampons was measured using the alkaline hematin technique; total menstrual fluid volume was simultaneously measured using a weighing technique and meticulous care to avoid evaporation.
RESULTS: Despite period-to-period change in measured total menstrual fluid and menstrual blood loss volumes, there was a significant correlation between total fluid volume and blood loss (r =.93, P <.001). Blood comprised 48% of total menstrual flow for women with moderately heavy blood loss (>60 mL) and 50% for women with excessive blood loss (>100 mL). Regression estimation of blood loss from total fluid volume was reasonably accurate. For clinical purposes, estimated blood volumes correctly classified 98% of periods in terms of actual blood loss as normal (<60 mL blood), moderately heavy (60-100 mL), or excessive (>100 mL).
CONCLUSION: If total fluid volume is measured carefully, the estimate of actual blood loss is sufficiently accurate for clinical purposes. This simple technique has considerable clinical potential, and inexpensive commercial packs for this purpose could easily be developed.
METHODS: Fifty-three women were studied over two menstrual periods each. Hemoglobin in menstrual pads and tampons was measured using the alkaline hematin technique; total menstrual fluid volume was simultaneously measured using a weighing technique and meticulous care to avoid evaporation.
RESULTS: Despite period-to-period change in measured total menstrual fluid and menstrual blood loss volumes, there was a significant correlation between total fluid volume and blood loss (r =.93, P <.001). Blood comprised 48% of total menstrual flow for women with moderately heavy blood loss (>60 mL) and 50% for women with excessive blood loss (>100 mL). Regression estimation of blood loss from total fluid volume was reasonably accurate. For clinical purposes, estimated blood volumes correctly classified 98% of periods in terms of actual blood loss as normal (<60 mL blood), moderately heavy (60-100 mL), or excessive (>100 mL).
CONCLUSION: If total fluid volume is measured carefully, the estimate of actual blood loss is sufficiently accurate for clinical purposes. This simple technique has considerable clinical potential, and inexpensive commercial packs for this purpose could easily be developed.
Full text links
Trending Papers
Management of adult-onset Still's disease: evidence- and consensus-based recommendations by experts.Rheumatology 2023 September 6
Management of epilepsy during pregnancy and lactation.BMJ : British Medical Journal 2023 September 9
Dilated cardiomyopathy: causes, mechanisms, and current and future treatment approaches.Lancet 2023 September 17
Midline incisional hernia guidelines: the European Hernia Society.British Journal of Surgery 2023 September 20
Beta-blocker therapy in patients with acute myocardial infarction: not all patients need it.Acute and critical care. 2023 August
AGA Clinical Practice Update on the Epidemiology, Evaluation, and Management of Exocrine Pancreatic Insufficiency: Expert Review.Gastroenterology 2023 September 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app