200 Hz flying-spot technology of the LaserSight LSX excimer laser in the treatment of myopic astigmatism: six and 12 month outcomes of laser in situ keratomileusis and photorefractive keratectomy.
Journal of Cataract and Refractive Surgery 2001 August
PURPOSE: To evaluate safety, efficacy, predictability, and stability in the treatment of myopic astigmatism with laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) using the 200 Hz flying-spot technology of the LaserSight LSX excimer laser.
SETTING: SynsLaser Clinic, Tromsø, Norway.
METHODS: This retrospective study included 110 eyes treated with LASIK and 87 eyes treated with PRK that were available for evaluation at 6 and 12 months, respectively. The mean preoperative spherical equivalent (SE) was -5.35 diopters (D) +/- 2.50 (SD) (range -1.13 to -11.88 D) in the LASIK eyes and -4.72 +/- 2.82 D (range -1.00 to -15.50 D) in the PRK eyes. The treated cylinder was 4.00 D in both groups. Eleven (8.5%) LASIK eyes and 8 (7.4%) PRK eyes had secondary surgical procedures before 6 and 12 months, respectively, and were excluded when the 6 and 12 month outcomes were analyzed.
RESULTS: None of the eyes lost 2 or more lines of best spectacle-corrected visual acuity. Seventy-seven percent of the LASIK eyes and 78% of the PRK eyes achieved an uncorrected visual acuity of 20/20 or better; 98% in both groups achieved 20/40 or better. The SE was within +/-0.5 D of the desired refraction in 83% of the LASIK eyes and 77% of the PRK eyes; it was within +/-1.0 D in 97% and 98%, respectively. The cylinder correction had a mean magnitude of error of 0.04 +/- 0.31 D (range -0.96 to +0.85 D) in the LASIK eyes and 0.02 +/- 0.37 D (range -1.44 to +0.72 D) in the PRK eyes. Refractive stability was achieved at 1 month and beyond in the LASIK eyes and at 3 months and beyond in the PRK eyes.
CONCLUSION: The outcomes of this study are comparable to those achieved with lasers that use small-beam technology with a lower frequency, as well as with other types of delivery systems. They suggest that the 200 Hz technology used in the LaserSight LSX excimer laser is safe, effective, and predictable and that with LASIK and PRK the results are stable when treating low to moderate myopia and astigmatism up to 4.0 D.
SETTING: SynsLaser Clinic, Tromsø, Norway.
METHODS: This retrospective study included 110 eyes treated with LASIK and 87 eyes treated with PRK that were available for evaluation at 6 and 12 months, respectively. The mean preoperative spherical equivalent (SE) was -5.35 diopters (D) +/- 2.50 (SD) (range -1.13 to -11.88 D) in the LASIK eyes and -4.72 +/- 2.82 D (range -1.00 to -15.50 D) in the PRK eyes. The treated cylinder was 4.00 D in both groups. Eleven (8.5%) LASIK eyes and 8 (7.4%) PRK eyes had secondary surgical procedures before 6 and 12 months, respectively, and were excluded when the 6 and 12 month outcomes were analyzed.
RESULTS: None of the eyes lost 2 or more lines of best spectacle-corrected visual acuity. Seventy-seven percent of the LASIK eyes and 78% of the PRK eyes achieved an uncorrected visual acuity of 20/20 or better; 98% in both groups achieved 20/40 or better. The SE was within +/-0.5 D of the desired refraction in 83% of the LASIK eyes and 77% of the PRK eyes; it was within +/-1.0 D in 97% and 98%, respectively. The cylinder correction had a mean magnitude of error of 0.04 +/- 0.31 D (range -0.96 to +0.85 D) in the LASIK eyes and 0.02 +/- 0.37 D (range -1.44 to +0.72 D) in the PRK eyes. Refractive stability was achieved at 1 month and beyond in the LASIK eyes and at 3 months and beyond in the PRK eyes.
CONCLUSION: The outcomes of this study are comparable to those achieved with lasers that use small-beam technology with a lower frequency, as well as with other types of delivery systems. They suggest that the 200 Hz technology used in the LaserSight LSX excimer laser is safe, effective, and predictable and that with LASIK and PRK the results are stable when treating low to moderate myopia and astigmatism up to 4.0 D.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app