Endovascular stent-graft treatment for diseases of the descending thoracic aorta.
European Journal of Cardio-thoracic Surgery 2001 September
OBJECTIVE: Assessment of endovascular stent-graft treatment for diseases of the descending thoracic aorta as a valid and effective alternative to surgery.
METHODS: From March 1999 to August 2000, a total of 16 patients underwent deployment of endovascular stent-grafts in the descending thoracic aorta. Patients were divided into three groups according to the type of lesion. Group A (n=8) included five patients with atherosclerotic aneurysm and three with chronic post-traumatic pseudoaneurysm. Patients with acute post-traumatic pseudoaneurysm (n=3) and type B aortic dissection (n=5) were included in Groups B and C, respectively. All patients underwent 5-mm chest spiral angio-computerized tomography (CT) scan and angiography as preoperative assessment. The deployed stent-graft systems were Talent-Medtronic and Excluder-Gore.
RESULTS: A total of 20 stent-grafts were placed. Two patients required deployment of two grafts, while three grafts were juxtaposed in a third patient in order to treat larger lesions. There was no mortality related to the procedure, although one patient (6.2%) died because of multiorgan failure 24h post-operatively. The placement of the graft was successful in all cases except one affected with type B dissection and characterized by a very large intimal flap, which was eventually fenestrated by graft guidewire. Therefore, an optimal sealing of the grafts was achieved in 15 patients. However, in one patient the descending aorta had to be surgically replaced because of the calcified pseudoaneurysm still compressing the trachea and left bronchus. Two patients required a left carotid-subclavian by-pass in order to achieve a sufficient neck for the proximal placement of the graft. No spinal cord injuries were observed. At the follow-up, performed with chest spiral angio-CT scan within 72 h and scheduled at 6 and 12 months and once a year, no stent-graft related complications have been detected.
CONCLUSIONS: Endoluminal stent-graft treatment may represent a valid option in well-selected cases of descending thoracic aorta diseases. A longer follow-up in a larger series of patients is desirable to confirm these initial positive results.
METHODS: From March 1999 to August 2000, a total of 16 patients underwent deployment of endovascular stent-grafts in the descending thoracic aorta. Patients were divided into three groups according to the type of lesion. Group A (n=8) included five patients with atherosclerotic aneurysm and three with chronic post-traumatic pseudoaneurysm. Patients with acute post-traumatic pseudoaneurysm (n=3) and type B aortic dissection (n=5) were included in Groups B and C, respectively. All patients underwent 5-mm chest spiral angio-computerized tomography (CT) scan and angiography as preoperative assessment. The deployed stent-graft systems were Talent-Medtronic and Excluder-Gore.
RESULTS: A total of 20 stent-grafts were placed. Two patients required deployment of two grafts, while three grafts were juxtaposed in a third patient in order to treat larger lesions. There was no mortality related to the procedure, although one patient (6.2%) died because of multiorgan failure 24h post-operatively. The placement of the graft was successful in all cases except one affected with type B dissection and characterized by a very large intimal flap, which was eventually fenestrated by graft guidewire. Therefore, an optimal sealing of the grafts was achieved in 15 patients. However, in one patient the descending aorta had to be surgically replaced because of the calcified pseudoaneurysm still compressing the trachea and left bronchus. Two patients required a left carotid-subclavian by-pass in order to achieve a sufficient neck for the proximal placement of the graft. No spinal cord injuries were observed. At the follow-up, performed with chest spiral angio-CT scan within 72 h and scheduled at 6 and 12 months and once a year, no stent-graft related complications have been detected.
CONCLUSIONS: Endoluminal stent-graft treatment may represent a valid option in well-selected cases of descending thoracic aorta diseases. A longer follow-up in a larger series of patients is desirable to confirm these initial positive results.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app