We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Elimination of mouse allergens in the working environment: assessment of individually ventilated cage systems and ventilated cabinets in the containment of mouse allergens.
Journal of Allergy and Clinical Immunology 2001 August
BACKGROUND: Laboratory animal allergy is an important occupational disease that is preventable by reduction of exposure to mammalian allergens.
OBJECTIVE: The purpose of this investigation was to assess the efficacy of safety equipment in containing mouse urinary protein (MUP)--specifically, individually ventilated cage (IVC) systems and class I--type and class II ventilated cabinets.
METHODS: Six IVC systems (which are used to house rodents) were operated at positive and negative pressure. Air samples (2 L/min) were collected at the cage front, cage back, air inlet, and air outlet, and the MUP was quantified by immunoassay. The background MUP of the IVC study room was compared with that of rooms where mice were housed conventionally or in isolators. Class I--type cabinets (n = 2) were tested during the disposal of soiled litter. Air samples were positioned on and behind the operator and inside the cabinet (n = 2). Personal samples were collected while scientific procedures were performed in a class II cabinet and in the open.
RESULTS: All of the IVC systems contained MUP effectively (>250-fold) when operated at negative pressure. At positive pressure, the "unsealed" IVC racks leaked MUP (1- to 25-fold reduction) but the "sealed" IVC system did not. Class I--type cabinets reduced (10-fold) but did not eliminate exposure during "cleaning out." No MUP was detected when procedures were performed in class II cabinets (protection factor, >10-fold).
CONCLUSION: Safety equipment can substantially reduce exposure to mouse allergen. Allergen exposure in holding rooms will be minimized if mice are housed in IVC systems operated at negative pressure or in "sealed" IVC systems at positive pressure. Respiratory protection should be used whenever "unsealed" IVC systems are operated at positive pressure or during "cleaning out" in class I--type cabinets.
OBJECTIVE: The purpose of this investigation was to assess the efficacy of safety equipment in containing mouse urinary protein (MUP)--specifically, individually ventilated cage (IVC) systems and class I--type and class II ventilated cabinets.
METHODS: Six IVC systems (which are used to house rodents) were operated at positive and negative pressure. Air samples (2 L/min) were collected at the cage front, cage back, air inlet, and air outlet, and the MUP was quantified by immunoassay. The background MUP of the IVC study room was compared with that of rooms where mice were housed conventionally or in isolators. Class I--type cabinets (n = 2) were tested during the disposal of soiled litter. Air samples were positioned on and behind the operator and inside the cabinet (n = 2). Personal samples were collected while scientific procedures were performed in a class II cabinet and in the open.
RESULTS: All of the IVC systems contained MUP effectively (>250-fold) when operated at negative pressure. At positive pressure, the "unsealed" IVC racks leaked MUP (1- to 25-fold reduction) but the "sealed" IVC system did not. Class I--type cabinets reduced (10-fold) but did not eliminate exposure during "cleaning out." No MUP was detected when procedures were performed in class II cabinets (protection factor, >10-fold).
CONCLUSION: Safety equipment can substantially reduce exposure to mouse allergen. Allergen exposure in holding rooms will be minimized if mice are housed in IVC systems operated at negative pressure or in "sealed" IVC systems at positive pressure. Respiratory protection should be used whenever "unsealed" IVC systems are operated at positive pressure or during "cleaning out" in class I--type cabinets.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app