We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Human pharmacokinetic and dosimetry studies of [(18)F]FHBG: a reporter probe for imaging herpes simplex virus type-1 thymidine kinase reporter gene expression.
Journal of Nuclear Medicine 2001 August
UNLABELLED: 9-[4-[(18)F]fluoro-3-(hydroxymethyl)butyl]guanine ([(18)F]FHBG) has been used as a reporter probe to image expression of herpes simplex virus type-1 thymidine kinase (HSV1-tk) reporter gene in living animals. Our aim was to study the kinetics, biodistribution, stability, dosimetry, and safety of [(18)F]FHBG in healthy human volunteers, preparatory to imaging patients undergoing HSV1-tk gene therapy.
METHODS: [(18)F]FHBG was synthesized with a specific activity of 37,000--444,000 GBq/mmol and a radiochemical purity > 99%. Ten healthy volunteers consented to participate in the study. A transmission scan was obtained before bolus injection of 70.3--229.4 MBq [(18)F]FHBG into a hand vein, followed by dynamic PET imaging with 4 consecutive emission scans. Warmed hand-vein blood was withdrawn at various times after injection for blood time--activity measurements. Electrocardiography, blood pressure, and blood and urine pharmacologic parameters were measured before and after injection of the [(18)F]FHBG tracer (n = 5). The stability of [(18)F]FHBG in the urine was analyzed. Attenuation-corrected images were reconstructed using the ordered-subsets expectation maximization algorithm. Image region-of-interest time-activity data were used with the MIRD program to estimate absorbed radiation dosages.
RESULTS: [(18)F]FHBG had rapid blood clearance; only 8.42% +/- 4.76% (mean +/- SD) of the peak blood activity remained at approximately 30 min. The average ratio of plasma activity to whole-blood activity during the study was 0.91 +/- 0.04. Penetration of [(18)F]FHBG across the blood-brain barrier was not observed. The primary routes of clearance were renal and hepatobiliary. High activities were observed in the bladder, gut, liver, and kidneys, but <0.0002% of the injected dose per gram was observed in other tissues. In the urine, 83% of activity 180 min after injection was stable [(18)F]FHBG. Blood and urine pharmacologic parameters did not change significantly after injection of the [(18)F]FHBG tracer. The bladder absorbed the highest radiation dose.
CONCLUSION: [(18)F]FHBG has the desirable in vivo characteristics of stability, rapid blood clearance, low background signal, biosafety, and acceptable radiation dosimetry in humans. This study forms the foundation for using [(18)F]FHBG in applications to monitor HSV1-tk reporter gene expression.
METHODS: [(18)F]FHBG was synthesized with a specific activity of 37,000--444,000 GBq/mmol and a radiochemical purity > 99%. Ten healthy volunteers consented to participate in the study. A transmission scan was obtained before bolus injection of 70.3--229.4 MBq [(18)F]FHBG into a hand vein, followed by dynamic PET imaging with 4 consecutive emission scans. Warmed hand-vein blood was withdrawn at various times after injection for blood time--activity measurements. Electrocardiography, blood pressure, and blood and urine pharmacologic parameters were measured before and after injection of the [(18)F]FHBG tracer (n = 5). The stability of [(18)F]FHBG in the urine was analyzed. Attenuation-corrected images were reconstructed using the ordered-subsets expectation maximization algorithm. Image region-of-interest time-activity data were used with the MIRD program to estimate absorbed radiation dosages.
RESULTS: [(18)F]FHBG had rapid blood clearance; only 8.42% +/- 4.76% (mean +/- SD) of the peak blood activity remained at approximately 30 min. The average ratio of plasma activity to whole-blood activity during the study was 0.91 +/- 0.04. Penetration of [(18)F]FHBG across the blood-brain barrier was not observed. The primary routes of clearance were renal and hepatobiliary. High activities were observed in the bladder, gut, liver, and kidneys, but <0.0002% of the injected dose per gram was observed in other tissues. In the urine, 83% of activity 180 min after injection was stable [(18)F]FHBG. Blood and urine pharmacologic parameters did not change significantly after injection of the [(18)F]FHBG tracer. The bladder absorbed the highest radiation dose.
CONCLUSION: [(18)F]FHBG has the desirable in vivo characteristics of stability, rapid blood clearance, low background signal, biosafety, and acceptable radiation dosimetry in humans. This study forms the foundation for using [(18)F]FHBG in applications to monitor HSV1-tk reporter gene expression.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app